The display limit of the measurement value is ±95000. Make sure that the setting
value does not exceed the display limit.
•
Check the input range of your input device such as AD board before setting.
•
The decimal point position of measurement values varies with each model.
● Setting Procedure
Setting current a (current for measurement value A)
1
Display the "Analog Setting" screen
while in setting mode.
2
Press the [ENTER] key.
The "Analog
Output Selection" screen will be
displayed.
3
Press the [DOWN] key twice. The
"Current a" screen will be displayed.
4
Press
the [ENTER] key. The present set
value will be displayed. The leftmost digit
will be selected.
5
Press the [UP]/[DOWN] keys together to
change the selected digit. After all the
changed digits have blinked the sign can
be changed. For details, refer to page 3-8
"Making Setting Value Changes."
6
Press the [UP]/[DOWN] key to change the
value of the selected digit. (Example:
Changing the value to 5.000 [mA].)
7
Press the [ENTER] key to determine the
set value.