3-3-5
Output Settings
Judgment Output Selection
This function makes it possible to select the operation of the output block.
An alarm will not be output if "3-state" is selected.
The final decision process is done in digital measurements. When an alarm is
turned ON, the value will be set to +999.9999 with which judgment processing will
be performed, provided that a fixed value has been set with “digital output at
alarm”.
Judgment Output
Selection
Output operation
OUT1
OUT2
OUT3
Logic
Judgment
1
Judgment
2
Alarm
Independent
Judgment
1
Judgment
2
Alarm
2-state
Judgment
1
Judgment
2
Alarm
3-state
Judgment
1
Judgment
2
Judgment
3
*
indicates the default value.
Displacement (+)
Display
Threshold a
Threshold b
Output status
Output status
Output status
Output status
Output status
Output status
Output status
Output status
Output status
Output status
Output status
OUT1
ON (OPEN)
OFF
OUT2
ON (OPEN)
OFF
OUT1
ON (OPEN)
OFF
OUT2
ON (OPEN)
OFF
OUT1
ON (OPEN)
OFF
OUT2
ON (OPEN)
OFF
OUT1 (HI)
ON (OPEN)
OFF
OUT2 (GO)
ON (OPEN)
OFF
OUT3 (LO)
ON (OPEN)
OFF
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1-A-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...