Sensor head angle to the center of measurement target
for a diffuse reflection-type sensor
Mount the sensor head so that the emitter and
receiver will be located in parallel to each other
as shown in the illustration on the right-hand side.
Refer to “
6-1 Sensor Head Specifications
”
for the measurement center distance and
measurement range.
Model name
Measurement center
distance
Measurement range
HL-G103-A-C5
30 mm
±4 mm
HL-G103-S-J
HL-G105-A-C5
50 mm
±10 mm
HL-G105-S-J
HL-G108-A-C5
85 mm
±20 mm
HL-G108-S-J
HL-G112-A-C5
120 mm
±60 mm
HL-G112-S-J
HL-G125-A-C5
250 mm
±150 mm
HL-G125-S-J
●
Sensor head angle to the center of measurement target
for a specular reflection-type sensor
Attach so that the receiver will receive
light reflected directly as shown in the
figure to the right.
Model name
Measurement
center distance
Measuremen
t range
Installation
angle
HL-G103A-RA-C5
26.3 mm
±2 mm
15°
HL-G103A-RS-J
HL-G105A-RA-C5
47.3 mm
±5 mm
10.39°
HL-G105A-RS-J
HL-G108A-RA-C5
82.9 mm
±10 mm
7.53°
HL-G108A-RS-J
90°
Installation
angle
Ramco National