FORMAT
5
Read of Differential Data in Buffering Data
The following special command formats are used to read buffering
measurement data in signed differential sequence format.
Request communication data
Normal response data
Data is stored in the following head data format in the specified head point.
The difference from the previous data will be returned for data on the second
point and each succeeding point.
Head data format:
1-character 7-digit integral part (no zero suppress)
<Example using the reply command shown above>
+123.4567, +123.4719, +123.4512, +123.4607, +123.4602, +123.4561,
・・・
↑
↑
↑
↑
↑
(+0.0152) (-0.0207)
(+0.0095) (-0.0005)
(-0.0041)
・・・
FORMAT
6
Binary Read of Buffering Data
The following special command formats are used to read buffering
measurement data in binary sequence format.
Request communication data
%
# R L B
Sender no.
Command
BCC
CR
Head point:
00001 to 03000
End point:
00001 to 03000
%
$ R L B
±
Sender no.
Command
BCC
CR
1 2 3
5
4 5 6 7 + 1
2
Head point data
Difference data from second point to end point
0 7 +
2
-
9 5 - 5
4 1
・
・
・
-
Destination no.
Command
BCC
Head point:
00001 to 03000
End point:
00001 to 03000
%
# R L C
CR
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1-A-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...