Output Settings
Address
Item
Data Range
Write
Read
Remarks
DT00054
Judgment Output
Selection
0
~
+3
OK
OK
DT00064
Displacement
Judgment
Threshold a
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00065
(
Hi
)
DT00066
Displacement
Judgment
Threshold b
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00067
(
Hi
)
DT00068
Displacement
Judgment
Hysteresis
(
Lo
)
+0000000
~
+9500000
OK
OK
Data type:
2 word
DT00069
(
Hi
)
DT00055
Judgment Output
OFF-delay
0
~
+7
OK
OK
DT00088
Measurement Value
Display on Panel
0
~
+2
OK
OK
Analog Settings
Address
Item
Data Range
Write
Read
Remarks
DT00070
Analog Output
Selection
0
~
+1
OK
OK
DT00071
Analog
Scaling
Measureme
nt Value
A
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00072
(
Hi
)
DT00073
Analog
Scaling
Measureme
nt Value
B
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00074
(
Hi
)
DT00075
Analog
Scaling
Voltage
a
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00076
(
Hi
)
DT00077
Analog
Scaling
Voltage
b
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00078
(
Hi
)
DT00079
Analog
Scaling
Current
a
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00080
(
Hi
)
DT00081
Analog
Scaling
Current
b
(
Lo
)
-9500000
~
+9500000
OK
OK
Data type:
2 word
DT00082
(
Hi
)
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1-A-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...