Laser Control
This function is used to select the laser emission/stop.
This function makes it possible to stop unrequired laser emission while the system
is not in measurement operation.
Setting
Function
Panel display
Emission
Laser emission is ON
Stop
Laser emission is OFF
*
indicates the default value.
The system will be in a data unficed state when the laser control is set to "Stop,"
and the data unstable state continues until "Emission" is set again.
The state returns to the measurement state when the laser is emitted again.
● Setting Procedure
1
Display the "System Setting" screen
while the system is in setting mode.
2
Press the [ENTER] key. The "Timing
Mode" screen will be displayed.
3
Press the [DOWN] key once. The
"Laser Control" screen will be displayed.
4
Press
the [ENTER] key. The ON/OFF
will be displayed.
5
Press the [UP]/[DOWN] key to select
ON/OFF. (Example: Changing the
selection to OFF.)
6
Press the [ENTER] key to determine
the set value.