Class
Function
Details
Initial value
Memory
change*
Ref.
page
Ou
tpu
t S
etti
ng
s
Judgment Output
Selection
Sets the operation of the output block.
Default: 2-state
Displace
ment
Judgment
Threshold a
Sets threshold a
and threshold b.
Default: +(detection range)
Default: -(detection range)
Threshold b
Hysteresis
Sets the hysteresis.
Default: +(0.2% of setting range)
Judgment Output OFF
Delay
Delays the timing of judgment output switched OFF
from ON.
Default: OFF
Measurement Value
Display on Panel
Turns OFF the rightmost digits on the digital display.
Default: SET 1
An
alo
g S
et
ting
s
Analog Output
Selection
Selects the desired output type from current output and
voltage output.
Default: Current output
Analog
Scaling
Meas A
Performs scaling
the analog current
output and the
analog voltage
output to any
desired value.
Default: Negative measurement range
Meas B
Default: Positive measurement range
Current a
Default: +4.000 mA
Current b
Default: +20.000 mA
Voltage a
Default: 0.000 V
Voltage b
Default: 10.000 V
Al
arm
S
etti
ng
s Analog Output at Alarm
Sets the analog output status at alarm operation.
Default: Holds previous value
Digital Output at Alarm
Sets the digital output status at alarm operation.
Default: Holds previous value
Alarm Delay Times
Holds the previous normal value up to the setting
number of times if an alarm is issued.
Default: 8 times
CO
M
S
et
tings
Terminating Resistor
Selection
Selects the terminating resistor for the sensor head
connecting to the host device over RS-422/485.
Default: R3
Sensor no.
Sets the number of each sensor head multi connected
to an RS-485 device.
Default: 01
Baud rate
Sets the communication speed.
Default: 38400 bps
Connection Mode
Selects the performance settings for measurement data
output to the host device.
Default: RS-485 Multiple
Sending Delay Time
Set the sensor's delay time in response to each
command transmitted from the host device.
Default: 0ms
Sys
tem
S
et
tin
gs
Timing Mode
Sets the timing input mode.
Default: Hold
Laser Control
Switches laser emission/stop.
Default: Emission
Eco Mode
Turns OFF the LED indicators on the control panel for
energy saving while the system is in RUN mode.
Default: Eco OFF
View Version
Displays the program version of the sensor.
-
Initialization
Initializes the memory settings currently in use.
Save
Saves all memory settings.
Timing
Holds the measurement value.
Default: OFF
-
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1-A-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com...