17-4
17.1.4 Common Specifications
Item
Description
2-axis type
4-axis type
8-axis type
Number of axes controlled
2 axes/1 system
4 axes/1 system
8 axes/1 system
Interpolation control
2-axis linear interpolation,
2-axis circular interpolation
2-axis linear interpolation, 3-axis linear interpolation
2-axis circular interpolation, 3-axis spiral interpolation
Occupied I/O points
Input: 128 points, Output: 128 points (SX128, SY128)
A
ut
om
at
ic
oper
at
ion
P
os
iti
on c
ont
rol
Position setting
modes
Absolute (absolute position setting), Increment (relative position setting)
Position setting
units
pulse
µ
m (Minimum command unit is selected from 0.1
µ
m or 1
µ
m.)
inch ((Minimum command unit is selected from 0.00001 inch or 0.0001 inch.)
degree ((Minimum command unit is selected from 0.1 degree or 1 degree.)
Position command
range
Pulse: -1,073,741,823 to 1,073,741, 823 pulse
µ
m (0.1
µ
m): -107,374,182.3 to 107,374,182.3
µ
m
µ
m (1
µ
m): 1,073,741,823 to 1,073,741,823
µ
m
inch (0.00001 inch): -10,737.41823 to 10,737.41823 inch
inch (0.0001 inch): -107,374.1823 to 107,374.1823 inch
degree (0.1 degree): -107,374,182.3 to 107,374,182.3 degree
degree (1 degree): -1,073,741,823 to 1,073,741,823 degree
Speed command
range
Pulse:1 to 32,767,000 pps
µ
m: 1 to 32,767,000
µ
m/s
inch: 0.001 to 32,767.000 inch/s
degree: 0.001 to 32,767.000 rev/s
Acceleration/
deceleration
Linear acceleration/deceleration, S-shaped acceleration/deceleration
Acceleration time
0 to 10,000 ms (can set in 1 ms)
Deceleration time
0 to 10,000 ms (can set in 1 ms)
Number of
positioning tables
Each axis Standard area: 600 points, extended area: 25 points
C
ont
rol
m
et
hod
Independent
PTP control (E point control, C point control), CP control (P point control), Speed
control (J point control)
2-axis
inter-
polation
Linear E point, P point, C point control Composite speed or long axis speed specification
Circu-
lar
E point, P point, C point control Center point or pass point specification
3-axis
inter-
polation
Linear E point, P point, C point control Composite speed or long axis speed specification
Spiral E point, P point, C point control Center point or pass point specification
Start-up speed
Standard area: 3 ms or less, extended area: 5 ms or less
Other
functions
Dwell
time
0 to 32,767 ms (can set in 1ms)
Summary of Contents for FP2 Positioning Unit RTEX
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 31: ...Chapter 4 Power On Off and Items to Check ...
Page 36: ...4 6 ...
Page 37: ...Chapter 5 4BPreparation For Operation ...
Page 45: ...Chapter 6 5BI O Allocation ...
Page 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Page 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 50 ...
Page 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Page 118: ...8 16 ...
Page 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 141: ...Chapter 9 8BManual Operation JOG Operation ...
Page 146: ...9 6 ...
Page 147: ...Chapter 10 9BManual Operation Home Return ...
Page 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Page 159: ...Chapter 12 11BStop Functions ...
Page 162: ...12 4 ...
Page 163: ...Chapter 13 12BSupplementary Functions ...
Page 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 183: ...Chapter 14 Precautions During Programming ...
Page 187: ...Chapter 15 Errors and Warnings ...
Page 212: ...15 26 ...
Page 213: ...Chapter 16 Troubleshooting ...
Page 214: ...16 2 16 1 Cannot Communication With AMP ...
Page 215: ...Chapter 17 Specifications ...
Page 275: ...Chapter 18 Dimensions ...
Page 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Page 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Page 278: ...18 4 ...
Page 279: ...Chapter 19 Sample Programs ...
Page 283: ...19 5 ...
Page 286: ...19 8 ...
Page 288: ......