8-15
8.2
52B
Interpolation Control
Type of operations
For the interpolation control, there are 2-axis linear interpolation control, 2-axis circular interpolation
control, 3-axis linear interpolation control, and 3-axis spiral interpolation control. The following methods
are available to specify the operation of each interpolation control. Select any of them as usage. The
axes in the relation of an interpolation are called X axis and Y axis for the 2-axis interpolation, and are
called X axis, Y axis and Z axis for the 3-axis interpolation.
In each interpolation control, the E point control that uses one table, P point control and C point control
that uses multiple tables can be combined arbitrarily as positioning data.
For example, using the P point control enables the continuous interpolation control from the 2-axis linear
control to the 2-axis circular interpolation control. The acceleration time and deceleration time can be
specified individually. For the P point control and C point control, the E point should be set as the last
table.
Type
Operation specification method
Necessary data
2-axis
linear
interpolati
on control
Composite speed
Composite speed of X axis and Y axis
Long axis speed
Speed of long axis (Axis of which moving
distance is long)
2-axis
circular
interpolati
on control
Center point/CW direction
X-axis and Y-axis coordinate of center point
Center point/CCW direction
X-axis and Y-axis coordinate of center point
Pass point
X-axis and Y-axis coordinate of pass point on arc
3-axis
linear
interpolati
on control
Composite speed
Composite speed of X axis and Y axis
Long axis speed
Speed of long axis (Axis of which moving
distance is long)
3-axis
spiral
interpolati
on control
Center point/CW direction/
X-axis movement
Y-axis and Z-axis coordinate of center point
Center point/CCW direction/
X-axis movement
Y-axis and Z-axis coordinate of center point
Center point/CW direction/
Y-axis movement
X-axis and Z-axis coordinate of center point
Center point/CCW direction/
Y-axis movement
X-axis and Z-axis coordinate of center point
Center point/CW direction/
Z-axis movement
X-axis and Y-axis coordinate of center point
Center point/CCW direction/
Z-axis movement
X-axis and Y-axis coordinate of center point
Pass point/X-axis movement
Y-axis and Z-axis coordinate of pass point on arc
Pass point/Y-axis movement
X-axis and Z-axis coordinate of pass point on arc
Pass point/Z-axis movement
Y-axis and Z-axis coordinate of pass point on arc
Summary of Contents for FP2 Positioning Unit RTEX
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 31: ...Chapter 4 Power On Off and Items to Check ...
Page 36: ...4 6 ...
Page 37: ...Chapter 5 4BPreparation For Operation ...
Page 45: ...Chapter 6 5BI O Allocation ...
Page 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Page 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 50 ...
Page 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Page 118: ...8 16 ...
Page 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 141: ...Chapter 9 8BManual Operation JOG Operation ...
Page 146: ...9 6 ...
Page 147: ...Chapter 10 9BManual Operation Home Return ...
Page 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Page 159: ...Chapter 12 11BStop Functions ...
Page 162: ...12 4 ...
Page 163: ...Chapter 13 12BSupplementary Functions ...
Page 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 183: ...Chapter 14 Precautions During Programming ...
Page 187: ...Chapter 15 Errors and Warnings ...
Page 212: ...15 26 ...
Page 213: ...Chapter 16 Troubleshooting ...
Page 214: ...16 2 16 1 Cannot Communication With AMP ...
Page 215: ...Chapter 17 Specifications ...
Page 275: ...Chapter 18 Dimensions ...
Page 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Page 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Page 278: ...18 4 ...
Page 279: ...Chapter 19 Sample Programs ...
Page 283: ...19 5 ...
Page 286: ...19 8 ...
Page 288: ......