17-18
17.4.7 Torque Limit Area
- The output torque from the AMP to motor can be changed. The setting range of 1 to 5000 is equivalent
to 0.1 to 500.0 %.
- It cannot be changed during the positioning operation. The change done during the positioning
operation will be affected at the next start-up.
Bank Offset
address Name
Descriptions
Default
value
Setting
range
Unit
00H
0D8H
Torque limit
enabled flag
Sets whether to enable or disable the execution of the torque limit for
each axis. To enable the torque limit, set the corresponding bit to 1.
Bit
Name
Default
Description
0
Torque limit of axis 1
0
0: Torque limit disabled (Default)
1: Torque limit enabled
1
Torque limit of axis 2
0
2
Torque limit of axis 3
0
3
Torque limit of axis 4
0
4
Torque limit of axis 5
0
5
Torque limit of axis 6
0
6
Torque limit of axis 7
0
7
Torque limit of axis 8
0
15 to 8
-
-
-
0E0H
Torque limit
value of axis 1
Stores the torque limit value of axis 1.
3000
1 to
5000
0.1 %
0E1H
Torque limit
value of axis 2
Stores the torque limit value of axis 2.
3000
1 to
5000
0.1 %
0E2H
Torque limit
value of axis 3
Stores the torque limit value of axis 3.
3000
1 to
5000
0.1 %
0E3H
Torque limit
value of axis 4
Stores the torque limit value of axis 4.
3000
1 to
5000
0.1 %
0E4H
Torque limit
value of axis 5
Stores the torque limit value of axis 5.
3000
1 to
5000
0.1 %
0E5H
Torque limit
value of axis 6
Stores the torque limit value of axis 6.
3000
1 to
5000
0.1 %
0E6H
Torque limit
value of axis 7
Stores the torque limit value of axis 7.
3000
1 to
5000
0.1 %
0E7H
Torque limit
value of axis 8
Stores the torque limit value of axis 8.
3000
1 to
5000
0.1 %
17.4.8 Positioning Table Number Setting Area
Used to specify the table number to start the position control.
The setting ranges are 1 to 600 in the standard area, and 10001 to 10025 in the extended area.
Bank Offset
address Name
Descriptions
Default
value
Setting
range
Unit
00H
100H
Position control
starting table
number of 1st axis
Stores the table number of 1st axis
starting the position control.
1
1 to 600
10001 to
10025
-
101H
Position control
starting table
number of 2nd axis
Stores the table number of 2nd axis
starting the position control.
1
1 to 600
10001 to
10025
-
102H
Position control
starting table
number of 3rd axis
Stores the table number of 3rd axis
starting the position control.
1
1 to 600
10001 to
10025
-
103H
Position control
starting table
number of 4th axis
Stores the table number of 4th axis
starting the position control.
1
1 to 600
10001 to
10025
-
104H
Position control
starting table
number of 5th axis
Stores the table number of 5th axis
starting the position control.
1
1 to 600
10001 to
10025
-
105H
Position control
starting table
number of 6th axis
Stores the table number of 6th axis
starting the position control.
1
1 to 600
10001 to
10025
-
106H
Position control
starting table
number of 7th axis
Stores the table number of 7th axis
starting the position control.
1
1 to 600
10001 to
10025
-
107H
Position control
starting table
number of 8th axis
Stores the table number of 8th axis
starting the position control.
1
1 to 600
10001 to
10025
-
Summary of Contents for FP2 Positioning Unit RTEX
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 31: ...Chapter 4 Power On Off and Items to Check ...
Page 36: ...4 6 ...
Page 37: ...Chapter 5 4BPreparation For Operation ...
Page 45: ...Chapter 6 5BI O Allocation ...
Page 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Page 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 50 ...
Page 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Page 118: ...8 16 ...
Page 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 141: ...Chapter 9 8BManual Operation JOG Operation ...
Page 146: ...9 6 ...
Page 147: ...Chapter 10 9BManual Operation Home Return ...
Page 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Page 159: ...Chapter 12 11BStop Functions ...
Page 162: ...12 4 ...
Page 163: ...Chapter 13 12BSupplementary Functions ...
Page 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 183: ...Chapter 14 Precautions During Programming ...
Page 187: ...Chapter 15 Errors and Warnings ...
Page 212: ...15 26 ...
Page 213: ...Chapter 16 Troubleshooting ...
Page 214: ...16 2 16 1 Cannot Communication With AMP ...
Page 215: ...Chapter 17 Specifications ...
Page 275: ...Chapter 18 Dimensions ...
Page 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Page 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Page 278: ...18 4 ...
Page 279: ...Chapter 19 Sample Programs ...
Page 283: ...19 5 ...
Page 286: ...19 8 ...
Page 288: ......