7-37
7.15
48B
Data Monitor
The internal data of the positioning unit RTEX can be monitored.
Make the connection between a PC and PLC, and configure the settings. Then, select [Online]
→
[Data Monitor] in the menu bar. The following dialog is shown.
Axis [Group]
The axis No. and group names to be monitored.
Synchronous group
Displays the current synchronous group.
Synchronous mode
Displays the current synchronous mode.
Synchronous condition
Displays the current synchronous state (synchronous or
asynchronous).
Active table number
The table number that the positioning data is being executed or has
completed.
Auxiliary output code
Auxiliary output code
AMP current value(pulse)
Monitor the value of feedback pulses.
Current value after unit
conversion
Monitor the feedback value of the AMP after the unit conversion.
Torque command (%)
Monitor the torque command value of the AMP
Actual speed (rpm)
Monitor the actual speed (rpm) of the AMP.
State of axis
The operating states of axes or error and warning occurrences.
Error code
The latest error code when an error occurred.
Error clear
Clear the error by clicking this button, when an error occurred.
Warning code
Indicate the latest warning code when a warning occurs.
Warning clear
Clear the warning by clicking this button, when a warning occurred.
Help
Indicate the help regarding this function.
Close
Close this dialog.
Note:
If an recoverable error occurred in the positioning unit RTEX, click [Error Clear] to clear the error.
If a warning occurred in the positioning unit RTEX, click [Warning Clear] to clear the warning.
Summary of Contents for FP2 Positioning Unit RTEX
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 31: ...Chapter 4 Power On Off and Items to Check ...
Page 36: ...4 6 ...
Page 37: ...Chapter 5 4BPreparation For Operation ...
Page 45: ...Chapter 6 5BI O Allocation ...
Page 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Page 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 50 ...
Page 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Page 118: ...8 16 ...
Page 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 141: ...Chapter 9 8BManual Operation JOG Operation ...
Page 146: ...9 6 ...
Page 147: ...Chapter 10 9BManual Operation Home Return ...
Page 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Page 159: ...Chapter 12 11BStop Functions ...
Page 162: ...12 4 ...
Page 163: ...Chapter 13 12BSupplementary Functions ...
Page 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 183: ...Chapter 14 Precautions During Programming ...
Page 187: ...Chapter 15 Errors and Warnings ...
Page 212: ...15 26 ...
Page 213: ...Chapter 16 Troubleshooting ...
Page 214: ...16 2 16 1 Cannot Communication With AMP ...
Page 215: ...Chapter 17 Specifications ...
Page 275: ...Chapter 18 Dimensions ...
Page 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Page 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Page 278: ...18 4 ...
Page 279: ...Chapter 19 Sample Programs ...
Page 283: ...19 5 ...
Page 286: ...19 8 ...
Page 288: ......