15-16
15.2.4 Axis Operation Errors (From 3000H)
These are the errors occurred while various operations are being executed.
A: Available N/A: Not available
Error
code
Error name
Description
Object Clear
Countermeasures
3000H Not servo ready The axis that servo is not locked
was started.
Each axis
A Confirm the servo is locked while
each axis is operating.
3001H
Servo off
detection in
operation
The servo became off during the
operation being processed.
Each axis
A
Turn off the servo on input when
the Busy signal for the target axis
is not on.
Check the status of the AMP.
3005H
Main power
supply OFF
error
The servo on was requested when
the main power supply of the AMP
was off.
Each axis
A
- Turn the servo on after the main
power supply has been turned
on.
- Check the voltage of the main
power supply.
3010H Limit + signal
detection
The input on the plus side of the
limit turned on.
Each axis
A Move the motor into the range of
the limit by an operation such as
the JOG operation.
Check the limit signal is correct.
3011H Limit – signal
detection
The input on the minus side of the
limit turned on.
Each axis
A
3012H Limit signal error Both inputs on the plus and minus
sides of the limit turned on.
Each axis
A Check the status of the limit signal.
3020H
Software limit
(plus side)
detection
The movement amount of the
motor exceeded the upper limit of
the software limit.
Each axis
A Move the motor into the range of
the limit by an operation such as
the JOG operation.
Check the setting values of the
software limit.
3021H
Software limit
(minus side)
detection
The movement amount of the
motor exceeded the lower limit of
the software limit.
Each axis
A
3025H
Command
speed operation
error 1
The internal calculation of
command speed was overflowed. Each axis
A
- Slow down the setting speed.
- Check the settings of the pulse
number per rotation and
movement amount per rotation.
3026H
Command
speed operation
error 2
3027H
Command
speed operation
error 3
3030H Axis operation
error
An error occurred in the operation
processing of each axis due to any
reason.
Each axis
A
Check the setting values and
parameters of the positioning unit.
If the error occurred repeatedly
with the correct setting values,
please contact us.
3031H Operation
abnormal end
An error occurred in the operation
processing of each axis due to any
reason.
Each axis
All axes
A If the error occurred repeatedly,
please contact us.
3032H Axis group
operation error
- The setting of axis group was
changed during the operation or
when requesting the stop.
- An unconnected axis was
specified for the axis group.
Each axis
A
- Changing the axis group should
be performed when the axis
stops. Also, do not make the
stop request.
- Check the setting of the axis
group.
3033H Interpolation
operation error
The operation stopped as an error
occurred on other interpolation axis
during the interpolation operation.
Each axis
A
Check the setting values of the
positioning data for the
interpolation operation.
If the error occurred repeatedly
with the correct setting values,
please contact us.
3034H
Axis group not
settable
(In pulser
operation)
The setting of the axis group was
changed during the pulser
operation.
Each axis
A
Changing the axis group should
be performed when the pulser
operation enabled signal is off.
Summary of Contents for FP2 Positioning Unit RTEX
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 31: ...Chapter 4 Power On Off and Items to Check ...
Page 36: ...4 6 ...
Page 37: ...Chapter 5 4BPreparation For Operation ...
Page 45: ...Chapter 6 5BI O Allocation ...
Page 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Page 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 50 ...
Page 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Page 118: ...8 16 ...
Page 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 141: ...Chapter 9 8BManual Operation JOG Operation ...
Page 146: ...9 6 ...
Page 147: ...Chapter 10 9BManual Operation Home Return ...
Page 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Page 159: ...Chapter 12 11BStop Functions ...
Page 162: ...12 4 ...
Page 163: ...Chapter 13 12BSupplementary Functions ...
Page 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 183: ...Chapter 14 Precautions During Programming ...
Page 187: ...Chapter 15 Errors and Warnings ...
Page 212: ...15 26 ...
Page 213: ...Chapter 16 Troubleshooting ...
Page 214: ...16 2 16 1 Cannot Communication With AMP ...
Page 215: ...Chapter 17 Specifications ...
Page 275: ...Chapter 18 Dimensions ...
Page 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Page 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Page 278: ...18 4 ...
Page 279: ...Chapter 19 Sample Programs ...
Page 283: ...19 5 ...
Page 286: ...19 8 ...
Page 288: ......