15.2.5 Setting Value Errors (From 4000H)
These are the errors in the various setting values specified using the Configurator PM or ladder
programs.
A: Available N/A: Not available
Error
code
Error name
Description
Object Clear
Countermeasures
4000H Axis group setting error The settings of axis groups are
not correct.
Each axis
A
Check the following items
in the settings of the axis
group and independent
axis.
-
The same axis
number has been
registered in more than
one group.
-
Four or more axes
have been set in one
group.
-
The group is
composed of one axis
only.
4002H Unit setting error
The unit system for the axis
setting is out of the range.
Each axis
A
Check if the unit is one of
the followings.
Pulse, um, inch, degree
4004H Pulse number error per
rotation
The pulse number is out of the
range.
Each axis
A Check the setting value.
If the setting value is out of
the range, reduce it by the
following formula.
(Pulse number per rotation)
/ (Movement amount per
rotation)
4005H Movement amount
error per rotation
The movement amount is out of
the range.
Each axis
A
4010H Software limit setting
error
The upper or lower limit value of
software limit is out of the range. Each axis
A
Check the setting value.
If the error occurred
repeatedly with the correct
setting value, please
contact us.
4020H Limit stop deceleration
time error
The limit stop deceleration time is
out of the range.
Each axis
A
4021H Error stop deceleration
time error
The error stop deceleration time is
out of the range.
Each axis
A
4022H Emergency stop
deceleration time error
The emergency stop deceleration
time is out of the range.
Each axis
A
4028H Auxiliary output setting
error
The settings of auxiliary output
are not correct.
- A mode other than With mode or
Delay mode has been set for the
auxiliary output mode.
- A value other than 0 to 100 (%)
was specified for the auxiliary
output delay ratio in the delay
mode.
Each axis
A
4030H Synchronous group
setting error
The settings of synchronous
group are not correct.
- The same axis has been set for
the synchronous groups 1 and
2.
- Either master axis or slave axis
has not been set. (All bits are
off.)
- Multiple axes have been set for
the master or slave axis.
- The same axis has been set for
the master and slave axes.
- The slave axis has been set to
the interpolation group.
Each axis
A
Summary of Contents for FP2 Positioning Unit RTEX
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Page 21: ...Chapter 2 Parts and Functions ...
Page 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Page 24: ...2 4 ...
Page 25: ...Chapter 3 Wiring ...
Page 31: ...Chapter 4 Power On Off and Items to Check ...
Page 36: ...4 6 ...
Page 37: ...Chapter 5 4BPreparation For Operation ...
Page 45: ...Chapter 6 5BI O Allocation ...
Page 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Page 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Page 102: ...7 50 ...
Page 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Page 118: ...8 16 ...
Page 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Page 141: ...Chapter 9 8BManual Operation JOG Operation ...
Page 146: ...9 6 ...
Page 147: ...Chapter 10 9BManual Operation Home Return ...
Page 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Page 159: ...Chapter 12 11BStop Functions ...
Page 162: ...12 4 ...
Page 163: ...Chapter 13 12BSupplementary Functions ...
Page 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Page 183: ...Chapter 14 Precautions During Programming ...
Page 187: ...Chapter 15 Errors and Warnings ...
Page 212: ...15 26 ...
Page 213: ...Chapter 16 Troubleshooting ...
Page 214: ...16 2 16 1 Cannot Communication With AMP ...
Page 215: ...Chapter 17 Specifications ...
Page 275: ...Chapter 18 Dimensions ...
Page 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Page 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Page 278: ...18 4 ...
Page 279: ...Chapter 19 Sample Programs ...
Page 283: ...19 5 ...
Page 286: ...19 8 ...
Page 288: ......