Control
Functions
2-3
Amount of carrier passing TDC sensor
Toner density condition Sensor output voltage
Less
High
Lower than normal
Much
Low
Higher than normal
<Control>
The following controls are necessary for normal control of toner density
1)
Automatic adjustment of TDC sensor gain (during execution of F8-C09)
(to attain the standard reference level).
2)
Maintain the standard level by control of toner density during use.
<Explanation of the control system>
1)
Automatic adjustment of TDC sensor gain
Automatically adjust the reference through the TDC sensor by executing service
mode F8-09.
The operation flow is as shown below.
2. 2 Toner Density Control
To keep toner density(toner carrier ratio) in the developer unit constant, the TDC
sensor (toner density sensor) which is installed under the developer unit detects the
amount of carrier in the developer unit to control the toner density.
<Fundamentals>
The change in magnetic flux density in accordance with the amount of carrier
(magnetic power) in the developer (mixture of toner and carrier) is detected by the
TDC sensor and is converted to a voltage to control the toner density.
<Change of toner density and change of TDC sensor output voltage>
F8-09 start
CPU will check toner density sensor output. (2.5 V)
CPU will adjust sensor gain
control signal
Memory number will be changed to new number in memory.
(F6-21 or F6-26)
Toner density sensor output voltage will be adjusted to 2.5 V
Yes
No
Summary of Contents for FA-DS72
Page 8: ......
Page 236: ...27 Sheet Bypass Tray PM102 8 1 7 5 3 4 6 10 11 4 12 13 9 16 15 18 14 4 17 2 ...
Page 238: ...28 ADU PM801 16 8 1 4 14 12 10 11 11 13 13 6 7 8 16 9 5 3 2 15 ...
Page 360: ...1 4 7 10 8 9 5 6 2 3 1 Sorter Mounting Assembly ...
Page 362: ...1 2 5 J41 3 6 7 8 4A 4 2 Covers ...
Page 370: ...A 4 5 2 6 3 4 7 1 9 9 12 10 13 14 15 16 17 18 19 20 21 22 8 J22 M4 M2 J35 A 6 Drive Block ...
Page 379: ...1 2 3 4 5 6 7 10 8 9 1 Sorter ...
Page 381: ...1 A 3 4 5 12 13 15 9 10 11 6 7 8 16 2 14 13A J202 J202 J104 2 Covers ...