298
APR 2002
Edition 2.0
DP-1510P/1810P
/1810F/2010E
5.2.4.2.
Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Tonal Signal Table
Service Mode 4 for DP-1810F - Tonal Signal
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “4”.
Use “V” or “/\ “ to scroll to the desired Modem Test.
5
Press “2” and “START”.
6
Enter the signal number (1-7) to select the binary
signal.
7
Press "CLEAR" to end the signal generation. To select
another signal, repeat step 6.
8
Press "STOP" twice to return to standby.
Number
Signals
1
462 Hz
2
1080 Hz
3
1100 Hz
4
1300 Hz
5
1650 Hz
6
1850 Hz
7
2100 Hz
MMM-dd-yyyy 15:00
00%
SET MODE (1-4)
ENTER NO. OR V
SERVICE MODE
ENTER NO. OR V
MODEM TEST (1-5)
1:SIGNAL TEST
SIGNAL TEST
IDLE (ENTER 1-7)
TONAL TEST
1080Hz
SIGNAL TEST
IDLE (ENTER 1-7)
MMM-dd-yyyy 15:00
00%