5.2.4.4.
Binary Signal (V.34)
This Service Mode is used to check the binary signal output. Signals can be output to the line using the
following procedure. (V.34)
Binary Signal Table
Service Mode 4 for DP-1810F - Binary Signal
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “4”.
Use “V” or “/\ “ to scroll to the desired Modem Test.
5
Press “4” and “START”.
6
Enter the signal number (01-61) and press [SET] to
select the binary signal.
7
Press "CLEAR" to end the signal generation. To select
another signal, repeat step 7.
8
Press "STOP" twice to return to standby.
Number
Signals
Number
Signals
Number
Signals
01
V34 2400 sr 2400 bps
22
V34 3000 sr 9600 bps
43
V34 3429 sr 4800 bps
02
V34 2400 sr 4800 bps
23
V34 3000 sr 12000 bps
44
V34 3429 sr 7200 bps
03
V34 2400 sr 7200 bps
24
V34 3000 sr 14400 bps
45
V34 3429 sr 9600 bps
04
V34 2400 sr 9600 bps
25
V34 3000 sr 16800 bps
46
V34 3429 sr 12000 bps
05
V34 2400 sr 12000 bps
26
V34 3000 sr 19200 bps
47
V34 3000 sr 19200 bps
06
V34 2400 sr 14400 bps
27
V34 3000 sr 21600 bps
48
V34 3429 sr 16800 bps
07
V34 2400 sr 16800 bps
28
V34 3000 sr 24000 bps
49
V34 3429 sr 19200 bps
08
V34 2400 sr 19200 bps
29
V34 3000 sr 26400 bps
50
V34 3429 sr 21600 bps
09
V34 2400 sr 21600 bps
30
V34 3000 sr 28800 bps
51
V34 3429 sr 24000 bps
10
V34 2800 sr 4800 bps
31
V34 3200 sr 4800 bps
52
V34 3429 sr 26400 bps
11
V34 2800 sr 7200 bps
32
V34 3200 sr 7200 bps
53
V34 3429 sr 28800 bps
12
V34 2800 sr 9600 bps
33
V34 3200 sr 9600 bps
54
V34 3429 sr 31200 bps
13
V34 2800 sr 12000 bps
34
V34 3200 sr 12000 bps
55
V34 3429 sr 33600 bps
14
V34 2800 sr 14400 bps
35
V34 3200 sr 14400 bps
56
ANSam
15
V34 2800 sr 16800 bps
36
V34 3200 sr 16800 bps
57
CM
16
V34 2800 sr 19200 bps
37
V34 3200 sr 19200 bps
58
JM
17
V34 2800 sr 21600 bps
38
V34 3200 sr 21600 bps
59
INFO0c & TONEB
18
V34 2800 sr 24000 bps
39
V34 3200 sr 24000 bps
60
INFO0c & TONEA
19
V34 2800 sr 26400 bps
40
V34 3200 sr 26400 bps
61
PPh & AC & ALT
20
V34 3000 sr 4800 bps
41
V34 3200 sr 28800 bps
21
V34 3000 sr 7200 bps
42
V34 3200 sr 31200 bps
MMM-dd-yyyy 15:00
00%
SET MODE (1-4)
ENTER NO. OR V
SERVICE MODE
ENTER NO. OR V
MODEM TEST (1-5)
1:SIGNAL TEST
V.34 MODEM TEST
ENTER NO._
V.34 MODEM TEST
V34 2400sr 2400bps
V.34 MODEM TEST
ENTER NO._
MMM-dd-yyyy 15:00
00%
Summary of Contents for DP-1510P
Page 2: ...2 The contents of this Service Manual are subject to change without notice Published in Japan ...
Page 74: ...74 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 14 Remove the Cleaner Roller 640 14 ...
Page 83: ...83 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 29 Remove 2 Developer Felts 1041 29 ...
Page 289: ...289 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 Fuser Error Detection ...
Page 485: ...memo ...
Page 486: ...DZZSM00163 1 ...