273
DP-1510P/1810P
/1810F/2010E
APR 2002
Edition 2.0
5.2.2.
Service Mode 1 (Function Parameter Setting)
Use the following procedure to change the function parameters.
Note:
The following buttons provide these functions in the Service Mode:
Service Mode 1 : For DP-1810F
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “1”.
5
Enter the Function Parameter Number or press “V” or
“/\ “ to select the desired parameter.
Ex: Changing the "ALARM STATUS" -- Enter "001"
and press [SET].
6
Press “START”.
7
Enter the new setting value. Ex: Enter "3" for Constant.
8
Press “START”. The new value will be stored and the
next parameter will be displayed.
9
Repeat steps 4 through 7 to change other Function
Parameters or Press “STOP” twice to return to
standby.
"START":
:
The new setting value is stored in the machine.
"V”
:
Scroll the function parameter number down.
"/\ “
:
Scroll the function parameter number up.
MMM-dd-yyyy 15:00
00%
SET MODE (1-4)
ENTER NO. OR V
SERVICE MODE
ENTER NO. OR V
PARAMETER (000-299)
ENTER PARAMETER #_
PARAMETER #001
ALARM STATUS?
ALARM STATUS:Timer
1:OFF 2:Tmr 3:CONST
ALARM STATUS:Const.
1:OFF 2:Tmr 3:CONST
PARAMETER #002
STOP COMM.JRNL?
MMM-dd-yyyy 15:00
00%
Summary of Contents for DP-1510P
Page 2: ...2 The contents of this Service Manual are subject to change without notice Published in Japan ...
Page 74: ...74 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 14 Remove the Cleaner Roller 640 14 ...
Page 83: ...83 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 29 Remove 2 Developer Felts 1041 29 ...
Page 289: ...289 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 Fuser Error Detection ...
Page 485: ...memo ...
Page 486: ...DZZSM00163 1 ...