For Long and Trouble-Free Operation: Warning and Error Messages
85
F
o
r L
ong
and
T
roub
le
-F
re
e
O
per
a
tio
n
When there is a problem with unit status, a warning error “E-**” appears in the OSD display. Press the DIAG button to get
detailed error information.
Display of warning information for unit status
Display
Description
Deck operation
No
Character code
75
STORAGE INTERMITTENT
Displayed for 3 seconds when reduced storage device performance or other cause
has resulted in a dropout during clip playback.
Use a storage device with higher specifications.
Operation
continues
93
INVALID TC MODE
Appears during playback when the time code has been recorded in drop frame
mode. The video output is distorted and audio output is muted at the drop point of
the time code. Check the playback clip.
Playing back a 24p frame-rate clip requires that the time code be recorded in non-
drop frame mode.
Appears when the time code in an HD SDI input is in the drop frame mode during EE
or recording. Normal recording will not be possible under these conditions.
Check signal input to the unit. Set the input time code to non-drop frame mode.
(Appears when menu SETUP - SYSTEM - FREQUENCY is set to 23.98 Hz, 24 Hz, 59-
23 or 60-24.)
Operation
continues
95
INVALID EMBEDDED TC
Displayed when the time code does not advance at 1x speed when recorded video
frames are synchronized with HD SDI input. (Displayed when the SETUP - SYSTEM
- FREQUENCY menu setting is 59-23 or 60-24.)
Operation
continues
96
INVALID TC SEQUENCE
Appears during playback when frame rate data in user bits cannot be detected or
when the playback time code is not continuous. The video output is distorted and
audio output is muted in sections where the time code is not continuous. Check the
playback clip.
Appears during EE or recording when frame rate data cannot be detected in the user
bits data in an HD SDI input or when the input time code is not continuous. Normal
recording will not be possible under these conditions.
Check signal input to the unit. Input signals with a matching time code and pull-down
sequence.
(Appears when menu SETUP - SYSTEM - FREQUENCY is set to 23.98 Hz, 24 Hz, 59-
23 or 60-24.)
Operation
continues
97
NO ACTIVE FRAME
Appears when active frame data cannot be detected in the user bits in the HD SDI
input during EE or recording. Normal recording will not be possible under these
conditions.
Check signal input to the unit. The input signal must contain the active frame data
from a variable frame-rate camera.
(Appears when menu SETUP - SYSTEM - FREQUENCY is set to 59 - 23 or 60-24 and
VFR REC is set to ON.)
Recording is
disabled
*
2
Operation
continues during
recording
26
CARD ERROR<
>
Displayed when data was corrupted due to a P2 card error.
If generated during recording, the message will stay on after recording is stopped
until another operation takes place. (
indicates the slot number where the error
occurred.)
Replace the P2 card in the slot where the error occurred.
STOP
21
REC WARNING
Displayed when a video or audio error occurs during recording.
To continue operation, turn the power off and then back on again.
Corruption of an input signal during recording may terminate recording. Check
signal input to the unit.
STOP during
recording,
Operation
continues during
recording pause
due to corrupted
input signals
50
BATTERY EMPTY
Displayed when a drop in the backup battery voltage for the internal clock is
detected at power on.
*
1
Connect an AC adaptor and let the battery recharge for about 4 hours.
Operation
continues
*
1
After charging the battery, be sure to set the internal calendar and clock.
*
2
Recording is initially accepted after which operation is cancelled and recording is not possible.