LMX SERIES® OPERATION MANUAL
SECTION 4: Technical Specifications
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 47 of 463
4.10.9
320LMX AC Input
The Model 320LMX single-phase input voltages, required input currents at full rated load
and recommended service input currents are stated as below.
NO
INPUT VOLTAGE
INPUT CURRENT RECOMMENDED SERVICE
1
208 Vac
∆
±10%, 47-63 Hz
11 Arms
20 A
2
220 Vac
∆
±10%, 47-63 Hz
10 Arms
20 A
3
240 Vac
∆
±10%, 47-63 Hz
9 Arms
20 A
4
220/380 Vac ±10%, 47-63 Hz
6 Arms
15 A
5
230/400 Vac ±10%, 47-63 Hz
6 Arms
15 A
6
240/416 Vac ±10%, 47-63 Hz
6 Arms
15 A
7
277/480 Vac ±10%, 47-63 Hz
5 Arms
15 A
4.10.10
345LMX AC Input
The Model 345LMX single-phase input voltages, required input currents at full rated load
and recommended service input currents are stated as below.
NO
INPUT VOLTAGE
INPUT CURRENT RECOMMENDED SERVICE
1
208 Vac
∆
±10%, 47-63 Hz
23 Arms
40 A
2
220 Vac
∆
±10%, 47-63 Hz
22 Arms
40 A
3
230 Vac
∆
±10%, 47-63 Hz
21 Arms
40 A
4
240 Vac
∆
±10%, 47-63 Hz
20 Arms
40 A
5
220/380 Vac ±10%, 47-63 Hz
13 Arms
20 A
6
230/400 Vac ±10%, 47-63 Hz
12 Arms
20 A
7
240/416 Vac ±10%, 47-63 Hz
12 Arms
20 A
8
277/480 Vac ±10%, 47-63 Hz
11 Arms
20 A
4.10.11
360LMX AC Input
The Model 360LMX single-phase input voltages, required input currents at full rated load
and recommended service input currents are stated as below.
NO
INPUT VOLTAGE
INPUT CURRENT RECOMMENDED SERVICE
1
208 Vac
∆
±10%, 47-63 Hz
29 Arms
40 A
2
220 Vac
∆
±10%, 47-63 Hz
27 Arms
40 A
3
230 Vac
∆
±10%, 47-63 Hz
26 Arms
40 A
4
240 Vac
∆
±10%, 47-63 Hz
25 Arms
40 A
5
220/380 Vac ±10%, 47-63 Hz
16 Arms
20 A
6
230/400 Vac ±10%, 47-63 Hz
15 Arms
20 A
7
240/416 Vac ±10%, 47-63 Hz
15 Arms
20 A
8
277/480 Vac ±10%, 47-63 Hz
14 Arms
20 A
4
Cost Option
5
Cost Option
6
Cost Option