Query Syntax
[SOURce:]IMPEDance:L[:LIMit]:MAXimum?
Description
This command return the maximum allowable setting value for the L
component of the output impedance.
Parameters
None
Parameter Format
N/A
Query Example
IMPED:L:MAX?
0.00005000
Query Syntax
[SOURce:]IMPEDance:L[:LIMit]:MINimum?
Description
This command return the minimum allowable setting value for the L
component of the output impedance.
Parameters
None
Parameter Format
N/A
Query Example
IMPED:L:MIN?
0.00000000
Command Syntax
[SOURce:]IMPEDance:MODE
Description
This command sets the programmable impedance mode to either
Real-Time mode (0) or RMS Mode (1). See page 154 for a description
of both impedance modes.
0
Real mode.
1
RMS mode.
Note:
To change programmable impedance modes, the output of
the power source must be turned
OFF
first. Trying to change
modes while the output is ON will result in an error message.
Parameters
< 0 | 1 >
Parameter Format
<b>
Example
IMPED:MODE 1
Query Format
[SOURce:]IMPEDance:MODE?
Returned Data Format
<b>
Query Example
IMPED:MODE?
1