Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
Model #: PDUMH15ATNET
Single-Phase Auto Transfer Switch / Switched PDU, 15A 120V, 1U Horizontal Rackmount, 8 NEMA 5-15R
outlets, 2 NEMA 5-15P inputs
Highlights
Single phase 15A 120V Auto Transfer Switch / ATS PDU
Enables redundant-power option for single-corded network devices
Separate primary & secondary inputs connect to any two compatible power
sources
1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets
Individually switched outlets, network interface and 2 digit visual current meter
Description
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support
separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from
the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source
until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network
interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any
two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables
fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a
separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time.
Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate
mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates
power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front
input LED's display primary or secondary power availability.
Applications
ATS PDU systems provide a redundant power option with individual outlet control for single-corded network devices
Package Includes
PDU with attached 5-15P input power cord
Detachable C13 to NEMA 5-15P 12 ft/3.6m secondary input cord
Installable 1U mounting brackets
User manuals with warranty information
Features
120V 15A Power Disrtibution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched output receptacles (Agency de-rated to 12A
continuous)
ATS features provide redundant power for critical network equipment with a single input power cord
Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
Visual meter reports output power consumption in amps
8 switched NEMA 5-15R outlets; 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
Two NEMA 5-15P inputs connect to separate PRIMARY and SECONDARY power sources
ATS normally maintains output sourced from the primary input; As primary input power fails or becomes unstable, the ATS will switch to
power equipment from the secondary input until power on the primary input is restored and stable
ATS configurations enable hot-swappable UPS protection when used with a single UPS and redundant UPS protection when each input is
connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS similar to