8
Problem
Cause
>>
possible solution
●
No image or faulty image at RAW LINK A /
LINK B
Camera started incorrectly
>> Turn the WEISSCAM HS-2 off and
back on again
Respective port defective
>> Plug the BNC cable into the second
RAW port (single link)
BNC cable defective
>> Replace BNC cable
Target device defective or incompatible
>> Connect to another target device
(e.g. monitor)
>> The RAW signal cannot be processed
by tape recorders (e.g. SRW-1)
Signal transmission on the BNC cable
disrupted by another cable
>> Check the cable routing and bypass
possible sources of interference
●
●
●
●
●
Green image that appears in four quadrants
on the monitor
Monitor connected to the RAW LINK A /
LINK B, therefore RAW signal displayed
>> Connect monitor to the HD-SDI LINK A /
LINK B
●
WEISSCAM HS-2 is not detected by the
Hand Unit HU-2 (Stand alone version)
Hand Unit HU-2 initialised incorrectly
>> Turn the Hand Unit HU-2 and/or WEISS-
CAM HS-2 off and back on again
Connecting cable defective
>> Replace connecting cable
Radio channels do not match
(wireless mode)
>> Set the same radio channel on the Hand
Unit HU-2 and camin
>> If the camera still is not detected, the
camin may need to be updated
The camera output or Hand Unit HU-2
input is defective
>> Requires repair by a service partner
●
●
●
●
Multiple WEISSCAM HS-2 cameras cannot
be synchronised
Connecting cable (BNC) defective or
disrupted
>> Check and replace cable
No master camera specified
>> Master camera is specified via adapter
(short-circuit)
●
●