L-718-8-E
10
2.3.3 General Performance
NOTES:
※1 : CE mark compliant models apply only to DC powered, non-explosionproof specifications.
※2 : For transmission length of output signal, see sec. 5.7 "Output Signal and Power Terminal ldentification".
※3 : If signal cable length exceeds 200 meters, consult the factory.
※4 : This configuration meets the requirements for explosionproof certified system approved for the sensor unit and
transmitter combined.
※5 : This configuration meets the requirements for explosionproof certified equipment approved on the transmitter
alone (valid only for use in combination with high temperature service sensor except for CN003).
※6 : This explosionproof configuration applies only to remotely located models.
※7 : Bell 202 signal is superimposed over anaog output 1 (when combined with Smart Communication Unit "Link Top").
※8 : Flow signals below 0.3% of the maximum allowable flowrate is cut off.
※9 : If voltage pulse is selected, analog output is not available.
※10 : Of error outputs, "auto zero in progress" status output can be set up.
※ : Insulation resistance and dielectric strength tests are unacceptable.
Item
Description
Power source
85 to 264V AC, 50/60Hz or 20 to 30V DC (※1)
Power consumption
25VA max. or 10W max.
Ambient temperature
-20 to +50℃ (free of dew condensation)
Transmission length (remotely-located) (※2) 200 meters max. (using dedicated interconnect cable) (※3)
Applicable EU directives
EMC directive : 89/336/EEC, 92/31/EEC, 93/68/EEC
ATEX Directive : 94/9/EC
Applicable EN directives
EMC : EN55011 : 1998/A1 : 1999 Group 1 Class B EN61000-6-2 : 1999
ATEX : EN50021 : 1999
Explosionproof housing
TIIS
Combined explosionproof Exd [ib] IIB T3 or Exd [ib] IIB T4
(CN080 ... Exd [ib] IIA T3 or Exd [ib] IIA T4) (※4)
Exd (ib) IIB T2 (※5)
ATEX
EexnC [nL] IIB T3 (※6)
Dusttight and waterproof
IP66
Installation
Integrally mounted or remotely mounted (remote mount only for CN003 and one
combined with high temp. sensor unit)
Finish
Munsell 7.5G 7/2.5
Display
LCD display (7-segment 8-digit) provided
Weight
Integrally mounted type 4.6kg app. Remotely mounted type 5.8kg app.
Communication interface
Bell 202 (under HART protocol) (※7)
Pulse output (※8)
Open collector output (10V min. to 30V max., 50mA DC)
or voltage pulse (※9) "0" : 1.5V max. "1" : 15V min.
Output impedance 2.2kΩ
FS : 0.1 to10000Hz
Analog output (※8)
4 to 20mA DC Max. load 600Ω
Select two outputs from instant flowrate (mass or volume), temperature, or density.
Damping (default) : Flowrate 1 s, density 4 s, temperature 2.5 s.
Status output
Open collector output Normal : ON Error : OFF (30V, 50mA max.)
Select one output from error (default) (※10), flow direction, or hi/low alarm.
Status input
Contact-closure input (Form "a" contact) Close : 200Ω max. Open : 100Ω min.
Select one input from function OFF (default), remote zero, total count reset, or 0%
signal lock.
Item
Description
Model
CN003
CN006
CN010
CN015
CN025
CN050
CN080
Flowrate
Max. service range, kg/min
0 to 1.2
0 to 6
0 to 20
0 to 60
0 to 180
0 to 650 0 to 2000
Max. permissible range, kg/min
0 to 2.4
0 to 12
0 to 40
0 to 120
0 to 360 0 to 3000 0 to 4000
Min. range, kg/min
0 to 0.06
0 to 0.3
0 to 1
0 to 3
0 to 9
0 to 32.5 0 to 100
Factory
calibration
accuracy
Liquid
〔
±0.1% ± zero stability error
〕
of reading
Gas
〔
±0.5% ± zero stability error
〕
of reading
Reproducibility
Liquid
〔
±0.05% ±1/2 zero stability error
〕
of reading
Gas
〔
±0.25% ±1/2 zero stability error
〕
of reading
Zero stability, kg/min
0.00012
0.0006
0.002
0.006
0.018
0.065
0.2
Density
(Liquid)
Factory calib. accuracy(option)
0.3 to 2 g/mL
±0.001 g/mL
Analog accuracy
Respective accuracies ±0.1% of full scale
2.3.2 Transmitter (CT9401 : Sophisticated model)
Summary of Contents for Ultra mass MKII CN003
Page 66: ...L 718 8 E 66...
Page 67: ...L 718 8 E 67...
Page 68: ...L 718 8 E 68...
Page 69: ...L 718 8 E 69...
Page 70: ...L 718 8 E 70...
Page 71: ...L 718 8 E 71...