L-718-8-E
1.2 Transportation Considerations
(1) The OVAL flowmeter can best be transported to the installation site in the shipping container used for
transit from the factory.
(2) Avoid impact shocks and exposure to rainwater or other moisture during transit.
1.3 Storage Considerations
If the meter upon receipt is to be stored for extended periods of time before installation, unexpected
problems could arise. If such is the case, the following considerations should be taken;
(1) The flowmeter can best be stored in the original package used for transit from the factory.
(2) The place of storage should meet the following requirements:
●
Free from rain and water.
●
Free from vibration and impact shocks.
●
With least temperature and humidity variation (around 25
°
C
and 65% R. H.)
1.4 Operating Conditions
In order to maintain the design metering accuracy and long service life, it is essential that the ratings,
such as the flowrate, density, pressure, and temperature be held within the specified limits. These
operating conditions are stated on the tag, and in Sections 2.3 "General Specifications" and 2.4
"Product Code Explanation" in this manual. Do not fail to make sure of them before placing the meter in
service.
●
If the process fluid is corrosive, the meter materials must be considered for
compatibility.
●
If you want a change in operating conditions, consult the factory.
●
Some solid-mixed flows or some gas-mixed flows that are not homegeneous are not
measurable. Consult the factory.
1.5 Precautions at Installation
CAUTION:
To ensure accurate and stable measurement, the Coriolis flowmeter should be installed
in a location where pipeline oscillation will not exceed 0.3G.