Click Send
Reboot XLink
Another way is to use a USB thumb drive:
To do so, create file on USB thumb drive: \Sutron\XLink\AllStations_setup.txt
Place the following text in the file: RS232 BAUD RATE = 9600
Insert drive into XLink. Wait for LED to turn solid green (solid red means failure).
Remove Drive
Reboot XLink
Once setup with the display, please note the following:
X-Link Python scripts will no longer be able to use the RS-232 port.
LinkComm will not be able to connect to X-Link via the RS-232 port. Please use the USB port
instead.
To work with X-Link, the Display requires version 4.05 or newer
To work with the Display, X-Link requires version 8.27 or newer