Command
Description
BATT COIN
BATT COIN shows the voltage of the internal coin cell battery.
CUTOFF SYSTEM HIGH
CUTOFF SYSTEM LOW
CUTOFF TX HIGH
CUTOFF TX LOW
CUTOFF TEMP TX HIGH
CUTOFF TEMP TX LOW
CUTOFF DEADBAND
See
for additional details
Cutoff Tx High = 20.00 V, Range (14.00, 20.00)
Cutoff Tx Low = 9.00 V, Range (9.00, 13.00)
Cutoff Temp Tx High = 85.0 C, Range (40.0, 100.0)
Cutoff Temp Tx Low = -45.0 C, Range (-80.0, -20.0)
DIAG [0]
Shows system reset count. If followed by 0, it will clear system
resets. Use GET DIAG to access system diagnostics.
DIN1
DIN2
Shows state of digital input.
>DIN1
DIN1 is ACTIVE
>DIN2
DIN2 is NOT active
DOWNLOAD
See LOG
EXIT
Quits command line.
ERROR
Lists current errors. Clear with STATUS 0
FACTORY DEFAULTS
This command sets the setup to defaults, clears status (which
includes system errors and transmission counts), zeroes reset
counts, and clears asserts.
GET DIAG
Provides comprehensive diagnostic information, including status
and setup.
HELP
HELP SETUP
HELP LOG
HELP TX
HELP LOGIN
HELP SDI
HELP POWER
HELP OUTPUT
Brings up the help (lists commands).
HI
System replies with Hello and blinks green LED.
IRIDIUM MSG CHECK
Used to check for messages from the Iridium gateway. May incur
monetary charge.
[Mx] LAST [SCHED]
[CSV]
Shows the last measured reading of every active measurement. This
command does not make a new measurement, only shows the last
results of the last measurement. If preceded by the measurement
designator (E.g. M1 LEAS), it shows only one sensor.
SCHED If provided, the last scheduled reading is shown.
CSV If provided, the data is formatted in Sutron Standard CSV (same
format used for logged data) for both normal and machine mode
access.