Cutoff System High = 20.00 V, Range (14.00, 20.00)
Cutoff System Low = 9.00 V, Range (9.00, 13.00)
Cutoff Tx High = 20.00 V, Range (14.00, 20.00)
Cutoff Tx Low = 9.00 V, Range (9.00, 13.00)
Cutoff Temp Tx High = 85.0 C, Range (40.0, 100.0)
Cutoff Temp Tx Low = -45.0 C, Range (-80.0, -20.0)
Cutoff Deadband = 1.00 V, Range (0.00, 5.00), Default = 1.00
12.5
Iridium
Please see the
section for a description of these settings.
12.6
Cell
for information on these fields.
12.7
Time
12.7.1
Local Time Offset
Normally, stations will use UTC time to provide a standard time reference across stations that are in
multiple time zones.
If you would prefer to use local time, enter the time difference between local time and UTC in this field.
Note that daylight savings time is not considered.
12.7.2
Cell Time Sync Enable
12.8
Log Download Format
The settings in this section define the format of data downloaded from the station, whether the download
occurs in LinkComm, or to USB thumb-drive.
The
Format
setting may be “Standard CSV”,
“Legacy CSV”,
or “Custom”.