Station Rebooted: The time the station rebooted is sent along with the kind of reboot (power on,
watchdog reset, upgrade, etc.).
•
Recording on/off: When recording is started or stopped, a SMS message will be sent
•
Transmission failure
•
SDI-12 sensor failure
•
Measurement failure
•
Any error
The following settings control the events that cause notifications:
Notify On Bootup
Notify On Recording
Notify On Tx Fail
Notify On Alarms
Notify On SDI12 failure
Notify On Measurement error
Notify On Any error
Please note that there is some overlap between the error notifications.
Only one error notification is sent at a time, and only one error notification is sent per day. This means
that additional errors may be not be reported.
The cell modem will be kept on for 15 minutes after a notification is issued, allowing the customer to send
a follow up SMS to get more information. For example, replying to a notification SMS with the text
“!ERROR” will cause the station to reply with an SMS containing the list of errors.
All notifications have the same format. Up to two SMS are sent per notification; please note that not all
the data may fit. Here are some examples:
The station name is on the first line of the message.
The current station time is on the second line.
The next line contains the event that caused the notification, e.g.,
“Alarm In”,
“Error”.
If appropriate, error details are on the next line.
The most recent measurements are listed next, along with the alarm state for each. E.g. “TEMP
25.5 C”
At the end of the SMS are the number of transmissions made today, e.g. “TX3
today: good 31,
bad 3
”
Below is an example of a bootup notification. There is no measurement data because the system had no
time to make a reading.