125
Chapter 7
Administrator F
unctions
C
ALIBRATION
M
ODE
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
6.
Turn ON the torch switch, and confirm the difference between the output voltage displayed on the voltmeter
and the voltage displayed on the operation panel.
7.
Correct the difference by using the values of internal functions F41 and F42 so that the difference is within
the range of ±0.1 V.
●
When the value of F41 is “0.1", it is equivalent to the output current 0.1 V. To increases the output voltage, increase
the value to + side.
If the output current needs to be adjusted finely, change the value of F42. When the value of F42 is “0.01", it is
equivalent to the output current of 0.01 V.
8.
When you have adjusted the output voltage, turn ON the torch switch to confirm the adjusted result.
●
Make sure that the difference between the measured value and the value indicated on the operation panel is
within the range of ±0.1 V.
●
If the difference is out of this range, readjust the values of F41/F42.
9.
When the calibration has been completed, turn OFF the power switch of the welding power source, and then
turn ON the power source again after the operation panel has completely turned off.