60
F47
Special crater sequence
crater time
0.0 to 10.0
0.0 (s)
Sets crater time in the special crater sequence.
(available when F45 is enabled)
9
F48
Adjusting current with torch
switch
OFF/ON
OFF
With the setting of "Crater" and in the welding condition
(during start input holding), sets whether to adjust
current by the torch switch operation:
OFF: not to use torch switch
ON: uses torch switch (increase/decrease volume set
by F49 and F50 are applied).
9
F49
Current increase and
decrease by single-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by single
clicking of the torch switch. (available when "ON" is
selected in F48)
9
F50
Current increase and
decrease by double-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by double
clicking of the torch switch. (available when "ON" is
selected in F48)
9
F51
Special crater repeat
OFF/ON
OFF
With the setting of "Crater," sets whether to switch the
welding condition and crater condition by the click
operation of the torch switch:
OFF: not to use torch switch
ON: uses the torch switch
9
F52
Data type of data log
function
0 to 8
0
Sets sample data on the data log:
0: No sampling
1: Welding current / Welding voltage / Sequence
information
2: Current command / Voltage command / Feeding
command
3: Current command / Welding current / Welding
voltage
4: Current command / Welding current / Sequence
information
5: Welding current / Voltage command / Welding
voltage
6: Voltage command / Welding voltage / Sequence
information
7: Welding current / Feeding command / Sequence
information
8: Welding voltage / Feeding command / Sequence
information
-
F53
Sampling speed of data log
function
1/2/3
1
Sets sampling interval of the data log function:
1: 10 ms
2: 100 ms
3: 1 s
-
F54
Tack start process
OFF/ON
OFF
Sets whether to feed the wire with the slowdown speed
at the time of welding start:
OFF: Feeds with slow down speed
ON: Feeds without slow down speed
-
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with automatic machine made by
other manufacturer.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
F60 to
F66
No function
OFF (fixed)
OFF
No functions are provided.
-
F67
Setting change of current value
(initial condition, crater
condition)
OFF/ON
OFF
When “CRATER ON” is selected, sets the current value of
the initial condition and crater condition in the
percentage based on the current value of the welding
condition.
OFF: invalid
ON: settable with percentage
9
F68
Setting of current value (initial
condition)
10 to 300
100 (%)
Sets the current value of the initial condition in the
percentage based on the current value of the welding
condition.
9
No.
Function Name
Setting range
Initial value
Explanation
Memory