D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
116
The current welding conditions set with the operation panel will not be saved. (If necessary, record them in memory beforehand.)
The welding condition data recorded in the memory will be output in the way that the JOB Nos. (registration Nos.) are
displayed in a vertical line and the parameter values in a horizontally line.
Item
Description
Unit Item
Description
Unit
job_num
JOB No.
-255 to -155,
1 to 100
reserve
(reserved)
−
spot_tim
Arc Spot time
0.1 (s)
reserve
(reserved)
−
prf_tim
Pre-flow time
0.1 (s)
reserve
(reserved)
−
pre_iset
Initial current
1 (A)
ant_tim_adj
Anti-stick time adjustment
0.01 (s)
pre_vset
Initial voltage
0.1 (V)
ant_vset_adj
Anti-stick voltage
adjustment
0.1 (V)
pre_uni_vset
Initial voltage (synergic)
1 (±)
sldwn_adj
Slowdown adjustment
3.9 (IPM)
[0.1 (m/min)]
wld_iset
Welding current
1 (A)
up_slp_tim
Up-slope time
0.1 (s)
wld_vset
Welding voltage
0.1 (V)
dwn_slp_tim
Down-slope time
0.1 (s)
wld_uni_vset
Welding voltage (synergic)
1 (±)
pre_tim
Initial time
0.1 (s)
cre_iset
Crater current
1 (A)
cre_tim
Crater time
0.1 (s)
cre_vset
Crater voltage
0.1 (V)
KubireAutoAdj
Automatic correction of
[squeeze]
0/1(OFF/ON)
cre_uni_vset
Crater voltage (synergic)
1 (±)
KubireAutoSave
Saving [squeeze]
−
aff_tim
Post-flow time
0.1 (s)
KubireP1P
Spatter control P1P
1(±)
arc_char
Arc characteristics
1 (±)
KubireP2P
Spatter control P2P
1(±)
arc_char2
Arc characteristics
(reserved)
−
PerIset
Current value change
setting
0/1(OFF/ON)
pre_sens_slp
[Squeeze] detection
sensitivity (reserved)
−
PreIsetPer
Current value setting (initial
conditions)
1(%)
pre_sens_cnst
−
−
CreIsetPer
Current setting (crater fill)
1(%)
reserve
(reserved)
−
TsCrickIset
Torch switch current
adjustment
0/1(OFF/ON)
reserve
(reserved)
−
CriIsetStep1
Single click adjustment
value
1 (A)
reserve
(reserved)
−
CriIsetStep2
Double click adjustment
value
1 (A)
pre_feed
Initial feed speed
3.9 (IPM)
[0.1 (m/min)]
reserve
(reserved)
−
wld_feed
Welding feed speed
3.9 (IPM)
[0.1 (m/min)]
Interval
Interval welding
0/1(OFF/ON)
cre_feed
Crater feed speed
3.9 (IPM)
[0.1 (m/min)]
Interval_ON
Arc-ON time on interval
welding
0.01(s)
reserve
(reserved)
−
Interval_OFF
Arc-OFF time on interval
welding
0.01(s)
reserve
(reserved)
−
exp_ctrl
Extended control
information
−
ctrl
Sequence information
(*1)
dummy1 to 10
(reserved)
−
wmode_H
Process information 1
(*2)
chksum
Checksum
Checksum data
wmode_L
Process information 2
(*2)
−
−
−
*1: Crater sequence and other information is recorded.
*2: Wire diameter, material, shield gas and other process information is recorded.
"-" is shown for unused condition numbers.
Parameter of condition No.1
Parameter value
JOB No.