The internal function setting data will be output below the JOB Nos. (registration Nos.)
T I P S
•
It is not possible to separately save the welding condition data recorded in memory and the
internal function setting data. Both of the data will always be written in the
"DAIHEN_OTC_WELDING_PARAMETER.CSV" file.
•
When importing the backup data to the welding power source, both or either of the data
above can be imported at one time.
"ALL": Welding condition data recorded in Internal function setting data
"1": Welding condition data recorded in memory
"2": Internal function setting data
7.3.2
Simplified data log function
The welding status can be checked on a computer by sampling the data during welding and backing them up in the USB
memory. Only three of the following data can be sampled. Adding to this, the “Heat input” will be displayed in column E.
The data types/sampling speed should be specified in the internal function F52/F53 (data log function).
(
6.7
-
Setting Internal Functions)
Simplified data log will be created below the "DAIHEN_OTC_Welbee\DAT\DAT00001" folder. A csv file will be created
per welding.
When DAIHEN_OTC_Welbee\DAT\DAT00001 folder is already existing, "DAT00002" folder will be created below the
"DAIHEN_OTC_Welbee\DAT" folder and folder for the consecutive number will per created for each simplified data log.
Example: The data will be output as below when the internal function F52 is set to "1" (detected values of welding current,
welding voltage and feeding speed) and F53 to "2" (100 ms).
•
Welding current set value
•
Welding voltage set value
•
Wire feeding speed set value
•
Welding current actual value
•
Welding voltage actual value
•
Wire feeding speed actual value
Function setting data
Start of welding
Elapse of time
Time [msec]
Welding current [A]
Welding current [V]
Feeding rate [m/min]