81
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
4.
Turn the parameter adjustment knob, and change the setting value.
5.
Press the CANCEL key.
⇒
The setting of internal function completes, and the LCD display returns to the MENU screen.
'HWDLOHGLQIRUPDWLRQRQLQWHUQDOIXQFWLRQV
This section explains the detailed information of internal functions in the order of function No.
)6WDQGDUG([WHQGHGFDEOHPRGH
Sets the welding control status for extended cables for the application of STANDARD mode. This function is available
when travel speed is set to "STANDARD" and WELDING METHOD is set to "DC".
Extending the cables at the base metal side/torch side or power cables such as torch cables can cause extraordinary volume
of spatter. When this happens, turning this function ON (extended cable mode) can improve the status.
•
"ON": Extended cable mode
Set to "ON" for the length of extension cable longer than 99 ft (30 m). The LED of STANDARD starts flashing when
setting to "ON".
•
"OFF": Standard mode
T I P S
• In using the welding power source in the "HIGH" mode, the setting of this function is set to "OFF" and
cannot be changed.
• When the status is not improved even by setting of this function to "ON", combined use of the voltage
detection cable is recommended.
When using the voltage detection cable, set the internal function F38 (Arc voltage direct detection
switching) to "1". (
6.7.2.23
-
F38: Arc voltage direct detection switching)
)6ZLWFKLQJIXQFWLRQVZLWKUHPRWHFRQWURO
Sets the functions to be allocated to the switching knob of the analog remote control.
The selectable functions are “1” through “6” as shown in the below table. No function will be allocated if set at “0”.
⇒
The set value is activated as it is changed.
Setting
Function
0
No function
1
Crater setting
(
6.6.4 Crater setting
)
2
Gas check
(
5.3 Power ON and Gas Supply
)
3
Constant penetration
(
6.6.8 Penetration control adjustment
)
4
Tack start
(
6.7.2.35 F54 Tack start process
)
5
Reading welding conditions with remote control
(
6.7.2.27 F44: Reading welding conditions with remote control
)
6
No function
Summary of Contents for Welbee M350 II
Page 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Page 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Page 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Page 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...