S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
98
))&XUUHQWGLVSOD\DGMXVWPHQW*$,12))6(7
Set the adjustment value (gain/offset) when the current display value on the left digital meter is different from the actual
current value.
The current value displayed on the digital meter is obtained by software processing of the average value of outputs;
therefore, it may not be consistent with the value indicated on a needle meter, etc. When this happens, using this function
enables to finely adjust the current display value.
•
For F86, set gain, and for F87, set offset.
Changing the set value only corrects the display; the output welding current does not change.
•
For more information on the adjustment procedure, contact dealer.
NOTE
• Do not carelessly change the setting of this function.
))9ROWDJHGLVSOD\DGMXVWPHQW*$,12))6(7
Set the adjustment value (gain/offset) when the voltage display value on the right digital meter is different from the actual
voltage value.
The voltage value displayed on the digital meter is obtained by software processing of the average value of outputs;
therefore, it may not be consistent with the value indicated on a needle meter, etc. When this happens, using this function
enables to finely adjust the voltage display value.
•
For F88, set gain, and for F89, set offset.
Changing the set value only corrects the display; the output welding voltage does not change.
•
For more information on the adjustment procedure, contact dealer.
NOTE
• Do not carelessly change the setting of this function.
Summary of Contents for Welbee M350 II
Page 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Page 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Page 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Page 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...