69
Chapter 6
W
elding Condition
S
ETTING
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6HWWLQJ:HOGLQJ&RQGLWLRQV
This section explains how to set the welding conditions (welding mode or welding parameters).
:HOGLQJPRGHVHWWLQJ
Depending on the type of shield gas, wire material, etc., there are modes that can be combined and modes that cannot be
combined.
Available combination of the welding mode is listed in the table below.
6HWWLQJZHOGLQJFRQGLWLRQV
Set the welding conditions with HOME screen and screen operation knob.
1.
Select "WELDING METHOD" on the HOME screen.
WELDING
METHOD
GAS (*1)
WIRE MATERIALS
WIRE DIA. [in. (mm)]
TRAVEL SPEED
Penetration
adjustment
WB-M352
WB-M502
DC
CO
2
MILD STEEL
.030 / .035 / .040 / .045
(0.8/0.9/1.0/1.2)
.035 / .040 / .045 / .052 / 1/16
(0.9/1.0/1.2/1.4/1.6)
STANDARD (*2)/HIGH
Enable
MAG
(20% CO
2
)
MILD STEEL
.030 / .035 / .040 / .045
(0.8/0.9/1.0/1.2)
.035 / .040 / .045 / .052 / 1/16
(0.9/1.0/1.2/1.4/1.6)
STANDARD (*2)/HIGH
Enable
MILD STEEL CORED
.045 / .052 (1.2/1.4)
.045 / .052 / 1/16
(1.2/1.4/1.6)
STANDARD (*2)
Enable
METAL CORED
.045/.052 (1.2/1.4)
.045 / .052 / 1/16
(1.2/1.4/1.6)
STANDARD (*2)
Enable
STAINLESS CORED
.045 (1.2)
.045 / 1/16 (1.2/1.6)
STANDARD (*2)
Enable
MIG
(2% O
2
)
STAINLESS STEEL
.030 / .035 / .040 / .045
(0.8/0.9/1.0/1.2)
.040 / .045 / 1/16
(1.0/1.2/1.6)
STANDARD (*2)/HIGH
Enable
STAINLESS FERRITE
.030 / .035 / .040 / .045
(0.8/0.9/1.0/1.2)
.045 (1.2)
STANDARD (*2)/HIGH
Enable
MIG
(100% Ar)
SOFT ALUMINUM
.045 / 1/16 (1.2/1.6)
.045 / 1/16 (1.2/1.6)
STANDARD (*2)/HIGH
-
HARD ALUMINUM
.045 / 1/16 (1.2/1.6)
.045 / 1/16 (1.2/1.6)
STANDARD (*2)/HIGH
-
DC TIG
-
-
-
-
-
-
DC STICK
-
-
-
-
-
-
*1: Note that the "collective" voltage adjustment may not meet the appropriate condition if a mixing gas other than those with the following
mixing ratios is used.
MAG gas: Argon (Ar) 80 % + Carbon dioxide (CO
2
) 20 %
MIG gas: Argon (Ar) 98 % + Oxygen (O
2
) 2 %
MIG gas: Argon (Ar) 100%
*2: For "STANDARD" mode, the standard mode or extended cable mode (extended mode of power cable) is available.
(
6.7.2.1
-
F1: Standard/Extended cable mode)
●
Turn the screen operation knob and point the cursor to the
WELDING METHOD (e.g. DC).
●
Press the screen operation knob.
⇒
The setting screen of welding conditions of WELDING
METHOD will be displayed.
'&
0$*&2
0,/'67((/
ȭ
67$1'$5'
&5$7(5),//21
,1,7,$/&21',7,21
0(18
6(/(&7
(17(5
2))
21
Summary of Contents for Welbee M350 II
Page 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Page 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Page 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Page 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...