Operating instructions for Pool control-40.net filter control unit
Page: 33 (34)
Variables provided for communicating with the building automation system (date: 13.01.2015):
No.
Name
Read/
Write
Format
Range
Info
0003
User PIN
W
"####"
"0000" -
"9999"
Login
0013
Heating status text
R
ASCII text
0015
Filter system status text
R
ASCII text
0025
Filter system manual operation
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: toggle
0027
ECO mode (manual)
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: toggle
0100
Water temperature
R
"##.#"
0101
Solar temperature
R
"##.#"
0102
Air temperature
R
"##.#"
0110
Required water temperature
R/W
"##.#"
"00.1" - "40.0"
0123
Frost protection function
W
ASCII
'0', '1', 'i'
0: switch off
1: switch on
i: toggle
9000
Collective fault indicator
R
'#'
'0' - '1'
'0'=Off, '1'=On
9013
Heating status variable
R
'#'
'0' - '3'
'0'=Off
'1'=heat exchanger
'2'=solar heating
9019
Filter pump status variable
R
'#'
'0' - '3'
'0': pause
'1': ECO speed
'2': normal speed
'3': high speed
9025
Manual operation status variable
R
'#'
'0' - '1'
'0'=Off, '1'=On
9027
ECO mode status
R
'#'
'0' - '1'
'0'=Off, '1'=On