Operating instructions for Pool control-40.net filter control unit 

Page: 23 (34) 

Auxiliary output 

 

Press the   button. 

 

 

Use  the 

  and 

  buttons  to  scroll  through  the  menu  until  the 

display shows "auxil. output". 

Press  the 

  button  to  select  the  settings  for  the  auxiliary  output 

(U4).

 

Operating 

mode 

 

Press the   button to select the operating mode using the   and   
buttons. 

The following options can be set: 

 

 

The auxiliary output is permanently on. 

 

 

The auxiliary output is permanently off. 

 

 

The auxiliary output is controlled by its timer. 

Press the   button to save the setting. 

Timer 

 

Use  the 

  and 

  buttons  to  scroll  through  the  auxiliary  output 

settings until the display shown here appears. 

Press the   button to program the timer. (See Procedure described 
under Timer programming). 

Cycle time 

 

Use  the 

  and 

  buttons  to  scroll  through  the  auxiliary  output 

settings until the display shown here appears. 

Press the   button to set the cycle time using the   and   buttons. 
Press  the 

  button  to  save  the  setting.  The  auxiliary  output  is 

switched  on  and  off  on  the  basis  of  this  setting.  A  setting  of  0 
minutes means that there is no cycling of the auxiliary output on and 
off. 

Adjustment range 0 to 240 minutes, factory setting 0

 

ON period 

 

Use  the 

  and 

  buttons  to  scroll  through  the  auxiliary  output 

settings until the display shown here appears. 

Press the 

 button to set the ON period (pulse duration) using the 

 and 

 buttons. This does not affect the cycle time. Press the 

 

button to save the setting. 

Adjustment range 5 to 240s, factory setting 10s

 

Interlock 

 

Use  the 

  and 

  buttons  to  scroll  through  the  auxiliary  output 

settings until the display shown here appears. 

Press  the 

  button  to  use  the 

  and 

  buttons  to  select  whether 

the  auxiliary  output  is  meant  to  be  interlocked  to  the  filter  pump. 
Press  the 

  button  to  save  the  setting.  When  the  interlock  is 

enabled, the auxiliary output is only switched on during filtration. 

Factory setting: no interlock 

Network (LAN) 

 

Press the   button.

 

 

 

Use  the 

  and 

  buttons  to  scroll  through  the  menu  until  the 

display shows "network (LAN)". 

Press the   button to select to display the network parameters.

 

IP address 

 

Press the   button to display the current IP address for the unit.

 

Device ID 

 

Use the 

 and 

 buttons to scroll through the network details until 

the display shown here appears. 

Press the   button to display the device ID used to denote the unit 
in the 

 communications server.

 

User PIN 

 

Use the 

 and 

 buttons to scroll through the network details until 

the display shown here appears. 

Press the   button to display the current PIN number for the end 
customer. 

Summary of Contents for POOLcontrol-40.net

Page 1: ...ta Dimensions 325mm x 281mm x 168mm Operating voltage 400V 50Hz Power consumption of control unit approx 5VA depends on operating mode Switching capacity Pump max 8A 3 0 kW AC3 Heating max 3A 0 4 kW A...

Page 2: ...ower supply for a Pentair IntelliFlo pump 8 Connecting the power supply for a Pentair SuperFlo VS pump 8 Connecting the heating 9 Connecting the EUROTRONIK 10 for backwashing using a 6 way multiport v...

Page 3: ...17 Configuration menu 18 Filter pump 18 Type 18 Motor current 18 Motor protection 18 Startup time 18 ECO mode 19 Timer 19 Temperature reduction 19 Heating 19 Operating mode 19 Priority 19 Minimum swi...

Page 4: ...n 24 Internet connection 25 Using the osf communications server 25 Operating the unit via the web server 26 Home page 27 Icons in the status bar 27 Icons in the control bar 27 User login 27 System inf...

Page 5: ...terminal U4 auxiliary output can be timed to switch on and off by its own dedicated timer in the unit Terminal U3 dosing equipment carries 230 V only while filtration is running but is de energized ou...

Page 6: ...emoved when connecting a pump fitted with a thermal winding protection switch winding thermostat If the pump does not have a winding protection switch the link must remain screwed in place These termi...

Page 7: ...K terminals winding protection switch The option Filter pump type var speed pump must be selected for the filter pump in the configuration menu Always refer to the operating instructions for the pump...

Page 8: ...h mode level 3 must be assigned to speed levels 1 to 3 Connecting the power supply for a Pentair IntelliFlo pump An IntelliFlo pump can be controlled by the PC 40 using the Pentair Intellicom controll...

Page 9: ...e operated without a EUROTRONIK 10 unit terminals 3 and 5 must be connected together with a link Disconnect the connecting cable before doing so Connecting the slide valves for backwashing A 230V slid...

Page 10: ...g terminals 19 and 20 This contact is rated for a maximum load of 230V 4A Connecting a flow sensor A flow sensor or a pressure sensor can be connected between terminals 21 and 22 instead of the factor...

Page 11: ...cable in the overflow balancing tank It does not matter if the individual probes touch each other The probes are fixed above the tank using the probe holder The dedicated cables must be taken to a ju...

Page 12: ...Dry running protection pump ON probe terminal 37 and touches this probe the level control system automatically switches the filter pump back on c Automatic actuation If water displacement in the swimm...

Page 13: ...ake This valve must be connected to terminals U9 N of the control unit A suitable solenoid valve R part number 1090005804 is available from the range Temperature sensor The sensors can be connected ei...

Page 14: ...d at the solar collector output in good thermal contact with the returning water flow The temperature at the installation position for the temperature sensor must not exceed 80 C Air temperature senso...

Page 15: ...re not connected properly or are connected in the wrong order LCD The filter pump has been switched off by a connected EUROTRONIK 10 controller or the winding protection switch LCD The filter pump has...

Page 16: ...ttons to set the temperature you require in the range 0 1 C to 40 C 3 To save the required temperature press the button again If more than 10 seconds pass without any button being pressed when setting...

Page 17: ...he setting for the currently flashing text day hour or minutes OFF in the top line means switch off time 9 Press the button to save the timer setting 10 Repeat steps 1 9 if you wish to program further...

Page 18: ...p mode until the display shown here appears Press the button The display shows the instantaneous current consumption of the filter pump Motor protection Use the and buttons to scroll through the filte...

Page 19: ...d buttons Press the button to save the setting With priority off disabled the heating is only actuated during filtration operating times Factory setting priority off Minimum switching interval Use the...

Page 20: ...re appears Press the button to set the switch on difference difference between pool temperature and solar temperature using the and buttons Press the button to save the setting Adjustment range 0 5 to...

Page 21: ...5 C Backwashing Press the button Use the and buttons to scroll through the menu until the display shows backwashing Press the button to select the settings for backwashing using slide valves Operatin...

Page 22: ...n Level control Press the button Use the and buttons to scroll through the menu until the display shows level control Press the button to select the level control settings Type Press the button The di...

Page 23: ...s factory setting 0 ON period Use the and buttons to scroll through the auxiliary output settings until the display shown here appears Press the button to set the ON period pulse duration using the an...

Page 24: ...button to save the setting Solar temperature Use the and buttons to scroll through the sensor calibration menu until the display shown here appears Press the button to adjust the solar temperature ind...

Page 25: ...he POOLcontrol 40 net has been connected to an active network socket you can then switch on the power supply The web server in the POOLcontrol 40 net automatically locates the communications server an...

Page 26: ...nce the unit has established a connection to the network it can be operated via the built in web server You can use any web browser to communicate with the web server For connections from the Internet...

Page 27: ...s in progress The filter pump is running Heating is running Solar heating is running Icons in the control bar Navigate to system information page Navigate to home page Navigate to main menu Navigate t...

Page 28: ...phical display and for processing using spreadsheet software In this submenu the service engineer can make advanced settings for the filter installation login using Service PIN required Pool settings...

Page 29: ...ycle time and the ON period can be set here A cycle time of 0 minutes means that the output is not switched periodically You can also specify here whether the output is meant to be interlocked to the...

Page 30: ...nually on this page This is the page where the PIN numbers for users and service engineers can be changed If 0000 is set as the PIN then login using a PIN is not needed Hardware configuration On this...

Page 31: ...ating switches on off when the temperature readings are fluctuating You can also set here whether the solar temperature control has priority over the filter timer i e the temperature control can switc...

Page 32: ...URL invocation in the form http xxx xxx xxx xxx modify nnnn data where nnnn is the number of the variable to be changed and data represents the data to be stored Before the building automation system...

Page 33: ...tch on i toggle 0027 ECO mode manual W ASCII 0 1 i 0 switch off 1 switch on i toggle 0100 Water temperature R 0101 Solar temperature R 0102 Air temperature R 0110 Required water temperature R W 00 1 4...

Page 34: ...de Heating Solar heating Frost protection Backwashing Level control Auxiliary output Network Sensor calibration Relax and enjoy your swimming pool Hansj rgen Meier Elektrotechnik und Elektronik GmbH C...

Reviews: