Operating instructions for Pool control-40.net filter control unit
Page: 18 (34)
5. Press the button to clear the timer setting.
Configuration menu
Filter pump
Press the button.
Use the
and
buttons to scroll through the menu until the
display shows "filter pump".
Press the button again to select filter pump mode.
Type
Press the button.
The display shows the currently selected type of filter pump
(3-phase pump, single-phase AC pump or variable speed pump).
You can use the
and
buttons to change the selection. Press
the button to save the setting.
Factory setting: 3-phase pump
Motor current
Use the
and
buttons to scroll through the filter pump mode
until the display shown here appears.
Press the
button. The display shows the instantaneous current
consumption of the filter pump.
Motor
protection
Use the
and
buttons to scroll through the filter pump mode
until the display shown here appears.
Press the
button. The display shows the motor protection trip
current. You can use the
and
buttons to change the setting.
Press the button to save the setting.
Adjustment range 0.5 to 8A, factory setting 4A
Startup time
Use the
and
buttons to scroll through the filter pump mode
until the display shown here appears.
Press the
button to set the startup time using the
and
buttons. Press the button to save the setting.
The startup time is the time that elapses after the filter pump starts
running before the flow sensor reading is retrieved.
Adjustment range 5 to 60s, factory setting 10s