Operating instructions for Pool control-40.net filter control unit
Page: 30 (34)
Network settings
On this page you can specify the name that shall denote the unit in the
communications server.
In addition, you can set email addresses for automatic notification in the
event of a fault.
You can also disable the link to the
communications server here.
On this page, you can make settings for synchronizing the built-in clock
automatically with the Internet.
You can also specify whether the unit obtains its IP settings automatically
from the network (DHCP).
If they are not meant to be obtained automatically from the DHCP server,
you can specify the IP addresses of the unit manually on this page.
This is the page where the PIN numbers for users and service engineers
can be changed. If "0000" is set as the PIN, then login using a PIN is not
needed.
Hardware configuration
On this page, you can select which pool components you wish to configure.
On this page, you can select the type of filter pump.
For 3-phase pumps, you must also set here the electronic motor protector
to the rated current of the pump (specified on the type plate).
In addition, you can set the pump startup time, during which the flow sensor
input is not polled.
For variable speed pumps, you can also select here the pump speed during
solar operation.
This page is where you set the type of level control.
You can also set a time limit for topping up with water.
If a skimmer pool has been selected for level control, the minimum
switching interval for the solenoid valve can be set here.