Valve delay
Use the and buttons to scroll through the backwashing settings
until the display shown here appears.
Press the button to use the and buttons to set how long the
filter pump should stop running whenever the slide valves are
operated. Press the button to save the setting.
Adjustment range 0 to 120s, factory setting 0s
Fortnightly
Use the and buttons to scroll through the backwashing settings
until the display shown here appears.
Press the button to use the and buttons to set whether filter
backwashing should be performed only once a fortnight. Press the
button to save the setting.
Factory setting: disabled (weekly backwashing)
Use main drain
Use the and buttons to scroll through the backwashing settings
until the display shown here appears.
Press the
button to use the and buttons to set whether the
main drain (floor drain) should be opened during backwashing.
Press the button to save the setting.
Factory setting: backwashing without main drain
Level control
Press the button.
Use the
and
buttons to scroll through the menu until the
display shows "level control".
Press the button to select the level control settings.
Type
Press the button.
The display shows the currently selected type of level control
(skimmer pool or balancing tank ("collecting vessel")). You can use
the and buttons to change the selection. Press the button to
save the setting.
Factory setting: skimmer pool
Time limit
Use the and buttons to scroll through the level control settings
until the display shown here appears.
Press the button to set the time limit using the and buttons.
Press the
button to save the setting. After the set time has
expired, the solenoid valve is switched off regardless of the water
level.
Adjustment range 0 to 240 minutes, factory setting 60 minutes
0 means no time limit.
Minimum
switching
interval
Use the and buttons to scroll through the level control settings
until the display shown here appears.
Press the
button to set the minimum switching interval using the
and
buttons. Press the
button to save the setting. The
minimum switching interval is the time difference between switching
operations when using a mini float switch as sensor.
Adjustment range 10 to 180s, factory setting 10s