- 66 -
- 67 -
ORION
Hybrid Video System
-
Control (27 Bytes)
No
Data
Length
Explanation
1
Loop Out Channel
1 byte
Loop Out Channels from Image Processor Module :
0x00(DVI Loop In),0x01(DVI1), 0x02(DVI2),0x03(DVI3),0x04(DVI4)
2
Fan Status
1 byte
0x00 : Error , 0x01: Good
3
TBD
1 byte
TBD
4
IP Board 1 Input Channel
1 byte
0x00(DVI Loop In),0x01(DVI1), 0x02(DVI2),0x03(DVI3),0x04(DVI4)
5
IP Board 2 Input Channel
1 byte
0x00(DVI Loop In),0x01(DVI1), 0x02(DVI2),0x03(DVI3),0x04(DVI4)
6
IP Board 3 Input Channel
1 byte
0x00(DVI Loop In),0x01(DVI1), 0x02(DVI2),0x03(DVI3),0x04(DVI4)
7
IP Board 4 Input Channel
1 byte
0x00(DVI Loop In),0x01(DVI1), 0x02(DVI2),0x03(DVI3),0x04(DVI4)
8
F/W Version
10 bytes
Board Name:3bytes, Year : 2bytes, Month : 2bytes, Day : 2bytes
Version Mode(Release or Test) : 1byte
Ex)Image Control Board, December 29
th
, 2012 Release
I/C(ASCII) 0x49 0x2F 0x43 0x01 0x02 0x01 0x02 0x02 0x09
R(ASCII) 0x52
9
F/W Version
10 bytes
Board Name:3bytes, Year : 2bytes, Month : 2bytes, Day : 2bytes
Version Mode(Release or Test) : 1byte
Ex)Matrix Switcher Board, December 29
th
, 2012 Release
MTX(ASCII) 0x4D 0x54 0x58 0x01 0x02 0x01 0x02 0x02 0x09
R(ASCII) 0x52
• ID Range (0x10~0x90): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IC Board(fixed as 0.) In case of
36 LCD sets or 9 Image Processor Module Sets, IDs will be 0x10, 0x20, 0x30, 0x40, 0x50, 0x60, 0x70, 0x80,and 0x90.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
D. Power Board Status
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
Power ID
Value
0X02
Variable
0X01
Variable
0x09
Variable
0x03
-
Send To MLCD
-
CMD : 0x87
• ID Range (0x19~0x99): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of Power Board(fixed as 9.) In
case of 4 LCD sets, current status information of 4 sets can be obtained by sending command with the ID of 0x19.
• IDs will be 0x19 for 4 sets, 0x29 for 8 sets, 0x39 for 12 sets,….and 0x99 for 36sets..
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
Power ID
Value
0X02
0x87
0X13
Variable
0x09
………….
Variable
0x03
-
Control(18 Bytes)
No
Data
Length
Explanation
1
Power Board 1 Status
1 byte
0:PowerOff(Stand-by), 1:PowerOn(Working)
2
Power Board 2 Status
1 byte
0:PowerOff(Stand-by), 1:PowerOn(Working)
3
Power Board 3 Status
1 byte
0:PowerOff(Stand-by), 1:PowerOn(Working)
4
Power Board 4 Status
1 byte
0:PowerOff(Stand-by), 1:PowerOn(Working)
5
Redundant Power Status
1 byte
It is all time Power Off. It will be turned on, if there is any abnormal
situation for Power 1, 2, 3, and 4
0:PowerOff(Stand-by), 1:PowerOn(Working)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Commands cannot be executed with Broadcast mode.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Control
Image Processor
Module ID
IP ID
Value
0X02
0x87
0x10
Variable
Variable
0x01
………..
Variable
0x03
-
Control(14 Bytes)
No
Data
Length
Explanation
1
Input Channel
1 Byte
0x01: DVI 1, 0x02: DVI 2, 0x03: DVI 3, 0x04: DVI 4, 0x05: DVI Loop In
2
Resolution
1 Byte
The Value of Display Resolution at the time of detection
3
Global Offset
1 Byte
0: Global Offset Off, 1: Global Offset On
4
Color Temperature
1 Byte
0: Normal Mode, 1: Studio Mode
5
F/W Version
10 Bytes
Board Name:3bytes, Year : 2bytes, Month : 2bytes, Day : 2bytes
Version Mode(Release or Test) : 1byte
Ex)Image Processor Board, December 29
th
, 2012 Release
I/P(ASCII) 0x49 0x2F 0x50 0x01 0x02 0x01 0x02 0x02 0x09
R(ASCII) -> 0x52
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
C. Image Control Board Status
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IC ID
Value
0X02
Variable
0X01
Variable
0x00
Variable
0x03
-
Send To MLCD
-
CMD : 0x87
• ID Range (0x10~0x90): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IC Board(fixed as 0.) In case of
36 LCD sets or 9 Image Processor Module Sets, IDs will be 0x10, 0x20, 0x30, 0x40, 0x50, 0x60, 0x70, 0x80,and 0x90.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Command cannot be executed with Broadcast mode.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IC ID
Value
0X02
0x87
0X1C
Variable
0x00
………….
Variable
0x03