- 52 -
- 53 -
ORION
Hybrid Video System
5.16. ORION Homepage log on and Version Information
• In order to move to Orion website, go to "Help" of menu bar ->
"OrionDisplay HomePage"
.
ORION Homepage Log on
• Go to "Help" of menu bar -> "About" to check MSCS.
Checking MSCS Version
-
PWR : Power Supply Board
-
IP : Image Processor Board
-
IC: Image Control Board
-
IR : Image Receiver Board
1. Power On
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0X40
0X01
Variable
Variable
Variable
0x03
-
Send To MLCD
-
CMD : 0x40
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.)
In case of 4 LCD sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0X40
0X01
0x00
Variable
0x03
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0X40
0X01
Variable
Variable
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
2. Power Off
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0X41
0X01
Variable
Variable
Variable
0x03
6. MSCS Protocol
Summary of Contents for OLW-4651