ORION
Hybrid Video System
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IR ID
Value
0X02
0x87
0X01
Variable
Variable
Variable
0x03
-
Send To MLCD
-
CMD : 0x87
• ID Range (0x15~0x98): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IR Board(5~8) In case of 4 LCD
sets, IDs will be 0x15, 0x16, 0x17, and 0x18.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Commands cannot be executed with Broadcast mode.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IR ID
Value
0X02
0x87
0X13
Variable
Variable
………….
Variable
0x03
-
Control (18 Bytes)
No
Data
Length
Explanation
1
Dimming Status
1 Byte
0(0x00)~100(0x64)
2
Temperature
1 Byte
0(0x00):0˚C ~127(0x7F):
127˚C / 128(0x80):
-1˚C~254(0xFE):-127˚C
0xFF: Temp Sensor Error
3
Elapsed Time
6 Bytes
54321 : 0x00 0x05 0x04 0x03 0x02 0x01
10 : 0x00 0x00 0x00 0x00 0x01 0x00
4
F/W Version
10 Bytes
Board Name : 3 bytes
Year : 2 bytes
Month : 2bytes
Day : 2bytes
Version Mode : (Release Or Test)
1 byte
Ex) Image Receiver Board, December 29
th
, 2012 Release
->I/R(ASCII)
0x49 0x2F 0x52
0x01 0x02 0x01 0x02
0x02 0x09
R(ASCII) -> 0x52
• ID Range (0x15~0x98): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IR Board(5~8) In case of 4 LCD
sets, IDs will be 0x15, 0x16, 0x17, and 0x18.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Image Processor Board Status
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0x87
0X02
Variable
Variable
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0x87
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IP ID
Value
0X02
Variable
0x02
Variable
Variable
………………………
Variable
0x03
-
Control Value : 0(0x00)~100(0x64)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
17. Multi Scale
-
The command for enlarging the screen of MLCD
A. General Command
STX
CMD
LENGTH
Data
Check
sum
ETX
ID
Master
XY
P
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X04
Variable
Variable
0x01
Variable
Variable
Variable
0x03
-
Send To MLCD
-
CMD : 0xDD(DVI 1), 0xDE(DVI 2), 0xDF(DVI 3), 0xE0(DVI 4), 0xE1(DVI 5)
• XY : the number of horizontal axis (X), the number of vertical axis (Y)
Upper 4bits(X- Max :15), lower 4bits(Y - Max:15)
• P : the enlarged position
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X02
Variable
Variable
0x01
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
18. Get Current Status
-
The command for getting the current information on IP, IR, IC, and Power.
A. Image Receiver Board Status