ORION
Hybrid Video System
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0x89
0X02
Variable
0x01
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
10. Factory Data
-
Apply the Picture Control values adjusted in the factory.
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X02
Variable
Variable
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0x82(Save), 0x83(Load)
• The command can be executed only for Power On status.
• The present Color Temperature value is indicated based on the current mode (Normal Mode/ Studio Mode.)
• Use “Get Picture Control Data” after sending the command to check whether the Data was applied properly.
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Commands cannot be executed with Broadcast mode.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X02
Variable
Variable
0x01
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
8. Firmware Default(Flash Screen Data Load)
-
Initialize the firmware as the phase before adjusting any values at the factory
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0x81
0X02
Variable
Variable
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0x81
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Commands cannot be executed with Broadcast mode.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0x81
0X02
Variable
Variable
0x01
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
9. Gamma Control
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Control
Image Processor
Module ID
IP ID
Value
0X02
0x89
0x03
Variable
Variable
0x01
Variable
Variable
0x03
-
Send To MLCD
-
CMD : 0x89
-
Control Value : 1(0x01)~6(0x06)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IP ID
Value
0X02
0x89
0X02
0x00
Variable
Variable
0x03