22. Equalizer Control
-
The command for compensating the input signal loss from the cable length.
-
CMD : 0x51
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Equalizer
Control
DE-
Emphasis
Control
Image Processor
Module ID
IR ID
Value
0X02
0x51
0x03
Variable
Variable
Variable
0x00
Variable
0x03
-
Send To MLCD
• Equalizer Control Value : 0(0x00),1(0x01),2(0x02),3(0x03),4(0x04),5(0x05),6(0x06),7(0x07)
• Recommendation for STP Cable
Format (Data Rate)
0~10m Cable
Over 10m Cable
1080P (1.65Gbps)
0~1
2~6
• Recommendation for UTP Cable
Format (Data Rate)
0~10m Cable
Over 10m Cable
1080P (1.65Gbps)
0~1
2~5
• ID Range (0x15~0x98): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IR Board(5~8.) In case of 4 LCD
sets, IDs will be 0x15, 0x16, 0x17, and 0x18.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Equalizer
Control
DE-
Emphasis
Control
Image Processor
Module ID
IR ID
Value
0X02
0x51
0x03
0x00
Variable
0x00
Variable
0x03
• Send the same command for all MLCD. No response will be made.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Equalizer
Control
DE-
Emphasis
Control
Image Processor
Module ID
IR ID
Value
0X02
0x51
0x03
Variable
Variable
Variable
0x00
Variable
0x03
• Equalizer Control Value : 0(0x00),1(0x01),2(0x02),3(0x03),4(0x04),5(0x05),6(0x06),7(0x07)
• ID Range (0x15~0x98): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IR Board(5~8.) In case of 4 LCD
sets, IDs will be 0x15, 0x16, 0x17, and 0x18.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
21. DE-Emphasis Get Current Status
-
The command for collecting the current configuration information of DE-Emphasis for compensating the output
signal loss based on the cable length.
-
CMD : 0x52
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0x52
0X01
Variable
0x00
Variable
0x03
-
Send To MLCD
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Command cannot be executed with Broadcast mode.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Equalizer
Current
Status
DE-
Emphasis
Current
Status
Image Processor
Module ID
IP ID
Value
0X02
0x52
0x03
Variable
Variable
0x00
Variable
Variable
0x03
-
DE-Emphasis Current Status Value : 0(0x00),1(0x01),2(0x02),3(0x03)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.