ORION
Hybrid Video System
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0X42
0X02
Variable
Variable
0x01
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
4. Input Mode Change
-
Convert the input mode without the scaling of LCD screen.
A. General Command
STX
CMD
LENGTH
Data
Check
sum
ETX
ID(1Byte)
Master
XY
X
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X04
Variable
Variable
0x01
0x11
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0xDD(DVI 1), 0xDE(DVI 2), 0xDF(DVI 3), 0xE0(DVI 4), 0xE1(DVI Loop In)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check
sum
ETX
ID(1Byte)
XY
S
X
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X04
0x00
0x11
0x00
0x01
Variable
0x03
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X02
Variable
Variable
0x01
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
-
Send To MLCD
-
CMD : 0x41
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0X41
0X01
0x00
Variable
0x03
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0X41
0X01
Variable
Variable
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
3. Information
-
Display the information on the LCD screen.
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0X42
0X02
Variable
Variable
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0x42
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
0x42
0X01
0x00
Variable
0x03
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.