ORION
Hybrid Video System
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Control
Image Processor
Module ID
IP ID
Value
0X02
0x88
0x0C
Variable
Variable
0x01
………..
Variable
0x03
-
Control(10 Bytes)
No.
Data
Length
Explanation
1
Brightness
1 byte
Range: 0(0x00)~100(0x64)
2
Contrast
1 byte
Range: 0(0x00)~100(0x64)
3
Sharpness
1 byte
Range: 0(0x00)~28(0x1C)
4
White Balance-Gain R
1 byte
Range: 0(0x00)~255(0xFF)
5
White Balance- Gain G
1byte
Range: 0(0x00)~255(0xFF)
6
White Balance Gain B
1byte
Range: 0(0x00)~255(0xFF)
7
White Balance – Offset R
1byte
Range: 0(0x00)~255(0xFF)
8
White Balance – Offset G
1byte
Range: 0(0x00)~255(0xFF)
9
White Balance – Offset B
1byte
Range: 0(0x00)~255(0xFF)
10
Gamma
1byte
Range: 0(0x00)~6(0x06)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
13. Test Pattern
-
The command for loading the embedded patterns on LCD screen.
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X02
Variable
Variable
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0x57(Red), 0x58(Green), 0x59(Blue), 0x5A(White), 0x5C(Test), 0x5B(Screen)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Image Processor
Module ID
IP ID
Value
0X02
Variable
0X01
0x00
Variable
0x03
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.
11. Dimming Control
-
The command for controlling the backlight of LCD
A. General Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IP ID
Value
0X02
0xDC
0X02
Variable
Variable
Variable
Variable
0x03
-
Send To MLCD
-
CMD : 0xDC
-
Control Value : 0~100(0x00~0x64)
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
B. Broadcast Command
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IP ID
Value
0X02
0xDC
0X02
0x00
Variable
Variable
0x03
-
Send To MLCD
• Send the same command for all MLCD. No response will be made.
-
Receive Data
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Control
Image Processor
Module ID
IP ID
Value
0X02
0xDC
0X02
Variable
Variable
Variable
Variable
0x03
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
12. Get Picture Control Data
-
The command for checking the current Picture Control Data of LCD
STX
CMD
LENGTH
Data
Check sum
ETX
ID(1Byte)
Master
Image Processor
Module ID
IP ID
Value
0X02
0x88
0X02
Variable
Variable
0x01
Variable
0x03
-
Send To MLCD
-
CMD : 0x88
• ID Range (0x11~0x94): Upper Byte is Image Processor Module Set ID(1~9) and Lower Byte is the ID of IP Board(1~4.) In case of 4 LCD
sets, IDs will be 0x11, 0x12, 0x13, and 0x14.
• Check Sum : Add values from STX to Data and execute logical operation “NOT.”
• Commands cannot be executed with Broadcast mode.