8 Error handling
−
75
−
•
No. of ALARM LED blinks: 9
Description Display
Operation
Causes Action
ACL
Subsystem error
Err29 Sub
System Error
1
An error occurred during
communication between
the main and sub CPUs.
Turn off the power, and then cycle the
power.
Invalid
Nonvolatile
memory error
Err41 Memory
Error
1
•
The stored data was
damaged.
•
Rewrite life of the
EEPROM (approx.
100,000 times) was
reached.
Initialize the operating data and
parameters in the controller using the
teaching pendant or data editing
software.
Invalid
8.3 Teaching pendant errors
If a communication error occurs between the teaching pendant and controller, the corresponding message will
be displayed and the screen will turn red.
If this screen is displayed, check the controller connection again and press the
[F1]
key.
Since this is not a controller error, no alarm code is shown nor the ALARM LED turns on.
The motorized actuator continues to perform the operation it was performing immediately before the error.
Error Pendant
display
Not connected
0 Q + & U F G V G E V G F
( % J G E M + & C I C K P
Communication error
% Q O ' T T Q T
( % J G E M + & C I C K P
( + I P Q T G ' T T + &
Not recognized
0 Q + & U F G V G E V G F
( % J G E M + & C I C K P