Addresses and codes lists
46
9
Addresses and codes lists
Refer to the
AZ
Series OPERATING MANUAL Function Edition for addresses and codes not described in this chapter.
This chapter describes the following.
•
Addresses and codes specific to the mini Driver
•
Addresses and codes not compatible with the mini Driver among those described in the
AZ
series OPERATING
MANUAL Function Edition
9-1
Addresses and codes specific to the mini Driver
In addition to addresses and codes specific to the mini Driver, this section describes addresses and codes specific to
the mini Driver among those described in the
AZ
Series OPERATING MANUAL Function Edition.
Monitor commands
Modbus
communication
Register address
Name
Description
Industrial
network
Command code
Upper
Lower
00D4h
(212)
00D5h
(213)
Direct I/O
Indicates the status of the extended input and the virtual
input. (Arrangement of bits
206Ah
(8298)
0148h
(328)
0149h
(329)
Main power supply
voltage
Indicates the voltage of the main power supply. (1=0.1 V)
20A4h
(8356)
014Ah
(330)
014Bh
(331)
DIP SW
Indicates the input status of the function setting switch
(SW1).
The table below shows the relation between the read
value and the function setting switch (SW1).
READ value SW1-No.3 SW1-No.2 SW1-No.1
0
ON
ON
ON
1
ON
ON
OFF
2
ON
OFF
ON
3
ON
OFF
OFF
4
OFF
ON
ON
5
OFF
ON
OFF
6
OFF
OFF
ON
7
OFF
OFF
OFF
20A5h
(8357)
0150h
(336)
0151h
(337)
RS485 Reception frame
counter
Indicates the number of times that a message was
received via RS-485 communication (Modbus).
20A8h
(8360)
0170h
(368)
0171h
(369)
I/O status 1
Indicates the ON-OFF status of the internal I/O.
(Arrangement of bits
20B8h
(8376)
0172h
(370)
0173h
(371)
I/O status 2
20B9h
(8377)
0174h
(372)
0175h
(373)
I/O status 3
20BAh
(8378)
0176h
(374)
0177h
(375)
I/O status 4
20BBh
(8379)
0178h
(376)
0179h
(377)
I/O status 5
20BCh
(8380)
017Ah
(378)
017Bh
(379)
I/O status 6
20BDh
(8381)
017Ch
(380)
017Dh
(381)
I/O status 7
20BEh
(8382)