Setting of switches
24
7-3
Address number (slave address)
Set the address number (slave address) by concurrently using the address number setting switch SW2 and the
function setting switch SW1-No.1. Make sure each address number (slave address) having set for each driver is not
duplicated.
Factory settings SW2: 1, SW1-No.1: OFF (address number 1)
The number of drivers that can be connected is different between Modbus RTU (RS-485
communication) and industrial network.
When using the driver with Modbus RTU (RS-485 communication)
The number of drivers that can be connected is 31 units maximum.
SW2
SW1-No.1
Address number
(slave address)
0
OFF
0 *
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
10
B
11
C
12
D
13
E
14
F
15
SW2
SW1-No.1
Address number
(slave address)
0
ON
16
1
17
2
18
3
19
4
20
5
21
6
22
7
23
8
24
9
25
A
26
B
27
C
28
D
29
E
30
F
31
* In the case of Modbus protocol, do not use the address number 0 (slave address 0) because it is reserved in the
broadcast mode.